P/N 3034040_H
Electrical Data
DEFROST DATA
Frequency (hr)
ELECTRIC DEFROST
Failsafe (minutes)
All models
Defrost Termination
Temperature (°F)
Note:
This data is based on store temperature and humidity that does not exceed 80°F and 55% R.H. unless otherwise stated.
Schedule defrost at night while lights are off.
Note: Run Amps values obtained under ambient conditions of 75°F and 55 % RH having IAT of Frozen Food category 0°F
following ASHRAE 72 method. Serial plate Total Amps obtained under UL471 testing conditions.
Evaporator Fans
Number of Motors
Amperes
Watts
Compressor LRA
Compressor RLA
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
12
35
48
VRL1B
1
0.3
32
30
4.8

PHYSICAL DATA

Refrigerant Charge (R290)
(0.150 kg each system)
VRL3B
10.6 oz
VRL2B
5.3 oz
VRL1B
4.58 oz
VRL2B
(2 Condensing Units for VRL3)
2
0.26
32
30
4.8
43
0.300 kg (2 systems)
0.150 kg (1 system)
0.130 kg (1 system)
VRL3B
2
0.26
32
28
4.45
VRL Merchandisers