Pairing With The Push Button - Dukane iQ Series Quick Start Manual

Multi-point controller with ethernet and net i/o
Hide thumbs Also See for iQ Series:
Table of Contents

Advertisement

Pairing with the Push Button

Connect the Ethernet port of the iQ Auto Plus to the NET I/O port of the MPC-E using a shielded
CAT 5e or better Ethernet cable (Dukane part number 200-1961-XXX).
1. Verify the STATUS LED color is White indicating the MPC-E is unpaired. If the STATUS LED is
White, then proceed to step 3. If the STATUS LED color is White to yellow blinking proceed to
step 2. See the STATUS LED table on page 14 for more information.
2. Push and hold the Push Button next to the "+24VDC", which is reached through the small hole
next to the "+24VDC" for 10 seconds.
3. The STATUS LED color should change to White to Blue blinking indicating that the MPC-E has
sent a pairing request and is awaiting a response. This may occur so quickly that it can't be seen.
4. The STATUS LED color should next change to White to Green blinking indicating that the
generator has responded to the MPC-E and pairing is in process. This may occur so quickly that
it can't be seen.
5. The STATUS LED on the MPC-E should change to Green indicating the generator and MPC-E
are paired.
iQ Series, MPC-E User's Manual
19