566D, 566E, 569D, 569F, 576C FACTORY-INSTALLED
OPTIONS
Dura-Shield Condenser Coils offer several options to match
coil protection to site conditions for optimum durability. See
table below. Consult your Bryant representative for further
information.
E-Coated Aluminum-Fin Coils have a flexible and durable
epoxy coating uniformly applied to all coil surfaces. Unlike brittle
phenolic dip and bake coatings, E-coating provides superior
protection with unmatched flexibility, edge coverage, metal
adhesion, thermal performance, and most importantly, corro-
sion resistance.
E-coated coils provide this protection since all coil surfaces are
completely encapsulated from environmental contamination.
This coating is especially suitable in industrial environments.
Pre-Coated Fin Coils provide protection in mild coastal
environments.
–20 F Low-Ambient Temperature Kit Option (Motormaster®)
(566E, 569D, 569F, 576C Only) controls outdoor-fan motor
operation to maintain the correct head pressure at low outdoor
ambient temperatures.
115-v Convenience Outlet (566E, 569D, 569F, 576C Only) to
power up electric drills, lights, and refrigerant recovery
machines. This means you are no longer required to run a sep-
arate 115-v power supply.
Al — Aluminum
FACTORY-INSTALLED
DURA-SHIELD
COIL PROTECTION
FACTORY-INSTALLED
CONVENIENCE OUTLET

OPTIONS AND ACCESSORIES

CONDENSER COIL OPTIONS
COPPER-TUBE COILS
WITH DURA-SHIELD
OPTION
Al Fins (Standard Coils)
Al Fins, E-Coated
Al Fins, Pre-Coated
LEGEND
LOW AMBIENT CONTROL
(FACTORY-INSTALLED OR
FIELD-INSTALLED)
Options and Accessories
Non-Fused Disconnect Switch (566E, 569D, 569F, 576C
Only) to remove power locally at the condensing unit. This
switch also includes a power lockout capability to protect the
service person. This lockout switch saves the service person
time and effort because there is no need to access a distant dis-
connect switch while servicing the unit.
FIELD-INSTALLED ACCESSORIES
Electric Unloader Package (576C120 Only) includes hard-
ware and solenoid valve to convert a pressure-operated
unloader to electric unloading.
–20 F Low-Ambient Temperature Accessory Kit (Motormas-
ter) controls outdoor-fan motor operation to maintain the correct
head pressure at low outdoor ambient temperatures.
Condenser Coil Grille Package protects condensing unit coil
from impact by large objects and vandalism.
Bryant's Line of Thermostats provide both programmable and
non-programmable capability with the new Debonair® line of
commercial programmable thermostats. The Commercial
Electronic thermostats provide 7-day programmable capability
for economical applications.
Hail Guard Package protects against damage from flying
debris and hail.
Gage Panel Package provides a suction and discharge pres-
sure gage for the refrigerant circuit.
ENVIRONMENT
Mild
Standard
Coastal
X
X
4
Industrial/
Coastal
X
FACTORY-INSTALLED
DISCONNECT SWITCH