Electrical Data - Bryant 566D User Manual

Commercial air-cooled condensing units with 524a air-handling units
Table of Contents

Advertisement

FACTORY-
UNIT
INSTALLED
SIZE
OPTION
NONE OR DISCONNECT
CONVENIENCE OUTLET
NONE OR DISCONNECT
072
CONVENIENCE OUTLET
NONE OR DISCONNECT
CONVENIENCE OUTLET
NONE OR DISCONNECT
CONVENIENCE OUTLET
NONE OR DISCONNECT
090
569D
CONVENIENCE OUTLET
NONE OR DISCONNECT
CONVENIENCE OUTLET
NONE OR DISCONNECT
CONVENIENCE OUTLET
NONE OR DISCONNECT
120
CONVENIENCE OUTLET
NONE OR DISCONNECT
CONVENIENCE OUTLET
NONE OR DISCONNECT
CONVENIENCE OUTLET
NONE OR DISCONNECT
576C
120
CONVENIENCE OUTLET
NONE OR DISCONNECT
CONVENIENCE OUTLET
NONE OR DISCONNECT
CONVENIENCE OUTLET
NONE OR DISCONNECT
569F
120
CONVENIENCE OUTLET
NONE OR DISCONNECT
CONVENIENCE OUTLET
LEGEND
FLA
— Full Load Amps
LRA
— Locked Rotor Amps
MCA
— Minimum Circuit Amps
MOCP — Maximum Overcurrent Protection
NEC
— National Electrical Code
RLA
— Rated Load Amps

ELECTRICAL DATA

569D072-120, 576C120, 569F120 UNITS
NOMINAL
VOLTAGE
VOLTAGE
RANGE*
V-Ph-Hz
MIN
MAX
208/230-3-60
187
254
460-3-60
418
506
575-3-60
523
632
208/230-3-60
187
254
460-3-60
418
506
575-3-60
523
632
208/230-3-60
187
254
460-3-60
418
506
575-3-60
523
632
208/230-3-60
187
254
460-3-60
418
506
575-3-60
523
632
208/230-3-60
187
254
460-3-60
418
506
575-3-60
523
632
*Units are suitable for use on electrical systems where voltage supplied
to the unit terminals is not below or above the listed limits.
NOTES:
1. The MCA and MOCP values are calculated in accordance with the
2. Motor RLA and LRA values are established in accordance with
3. The 575-v units are UL, Canada-listed only.
4. Convenience outlet is available as either a factory-installed option
26
FAN MOTORS
COMPRESSOR
(Qty 2)
RLA
LRA
FLA (ea)
19.2
146
0.9
9.6
73
0.4
7.7
58.4
0.4
25.6
190
1.5
12.8
95
0.7
10.2
76
0.7
37.8
239
1.5
17.2
125
0.7
13.4
80
0.7
36
198
1.5
18
99
0.7
14
79
0.7
16
125
1.5
8
66.5
0.7
6.4
50
0.7
NEC, Article 440.
Underwriters' Laboratories (UL), Standard 1995.
or a field-installed accessory and is 115-v, 1 ph, 60 Hz.
POWER
SUPPLY
LRA (ea)
MCA
MOCP
25.8
35
1.6
30.6
35
12.8
20
0.9
15.0
20
10.2
15
0.9
12.0
15
35.0
60
3.1
39.8
60
17.4
30
1.9
19.6
30
13.8
20
1.9
15.5
20
50.3
60
3.1
55.1
70
22.9
30
1.9
25.1
30
17.8
25
1.9
19.5
25
48.0
60
3.1
52.8
70
23.9
35
1.9
26.1
35
18.6
30
1.9
20.3
30
39.0
50
3.1
43.8
50
19.4
25
1.9
21.6
25
15.8
20
1.9
17.5
20