FACTORY- -INSTALLED OPTIONS (FIOPs)
j Open protocol RTU- - MP controller communicates to
LON, MODBUS, BACNET and Johnson N2 protocols.
j Through the base connectors for gas and electric
conduit/piping
j Stainless steel gas heat exchanger (includes tubes,
vestibule plate and collector box)
j Economizer with dry bulb sensing and barometric
relief
j Economizer with enthalpy sensing and barometric
relief
j 2 position motorized outdoor air damper
j Non- - fused disconnect
j Powered 115- - volt convenience outlet
j Non- - powered 115- - volt convenience outlet
j High static evaporator fan motor
j Return Air smoke detector
j Supply Air smoke detector
j CO
sensor
2
j Condenser hail guard - - louvered style
OPTIONAL WARRANTIES
j Complete Unit Parts only up to 5 years
j Complete Unit Parts and Labor up to 5 years
Many other optional warranties are available.
See the Commercial Start- - Up and Optional Extended
Warranty Price price pages for further information.

OPTIONS AND ACCESSORIES

FIELD INSTALLED ACCESSORIES
j Economi$ert IV- - electromechanical, gear driven with
j Economi$ert2- - compatible with DDC controls; gear
j Power exhaust
j Two- - position motorized outdoor air damper
j Manual outdoor air damper 25%
j Manual outdoor air damper 50%
j Roofcurb - - 14 inch (356mm) tall
j Roofcurb - - 24 inch (610mm) tall
j Thru- - the- - bottom connections- - electrical only
j Thru- - the- - bottom connections- - electrical and gas
j Condenser hail guard - - louvered style
j Flue shield
j Flue discharge deflector
j Liquid propane (LP) conversion kit
j High altitude conversion kit
j Phase monitor (loss of phase/phase reversal)
j Winter start kit, down to 25_F (- - 4_C)
j Low ambient head pressure controller,
j Low ambient head pressure controller,
j Time Guard II compressor anti- - cycle protection
Economizer Sensors
j Single Dry bulb control
j Differential Dry bulb control
j Single enthalpy control
j Differential enthalpy control
j CO
j CO
j CO
3
Belimo actuator (2- - 10v DC signal) and controller
driven with Belimo actuator (4- - 20mA) signal and
no controller
down to 0_F (- - 18_C)
down to - - 20_F (- - 29_C)
- - wall mounted
2
- - duct mounted
2
- - unit mounted
2

Hide quick links: