Ari Capacity Ratings - Bryant 566D User Manual

Commercial air-cooled condensing units with 524a air-handling units
Table of Contents

Advertisement

CONDENSING
UNIT
569D072
569D090
569D120
576C120
569F120
566D150
566E150
566D180
566E180
566D240
566E240
LEGEND
EER — Energy Efficiency Ratio
IPLV — Integrated Part Load Value
N/A — Not Applicable
SST — Saturated Suction Temperature
*Air Conditioning and Refrigeration Institute.
†Ratings in accordance with latest ARI Standard revisions.
**Condensing unit only ratings are at 45 F SST and 95 F entering-air temperature.
††E
S
® compliant combination of condensing unit and air handler/
NERGY
TAR
indoor coil.
ARI* CAPACITY RATINGS
AIR
HANDLER/
INDOOR COIL
524A-B072††
524A-C072††
524A-B090
524A-C090††
524A-B072
524A-C072††
524A-B090
524A-C090††
524A-B120
524A-C120
524A-B150
524A-C150
524A-B120
524A-C120
524A-B150
524A-C150
524A-B120
524A-C120
524A-B150
524A-C150
524A-B150
524A-C150
524A-B180
524A-C180
524A-B120
524A-C120
524A-B150
524A-C150
524A-B180
524A-C180
524A-B180
524A-C180
524A-B240
524A-C240
524A-B150
524A-C150
524A-B180
524A-C180
524A-B240
524A-C240
524A-C300
524A-C240
524A-B300
524A-C300
SOUND LEVELS, dB — 569D/576C/566D,E
SOUND RATING
UNIT
(60 Hz) dB (A)
072
80.0
569D
090
84.0
120
85.0
576C
120
83.0
150
86.2
566D
180
86.2
240
90.0
150
86.9
566E
180
87.5
240
88.0
ESTIMATED SOUND POWER LEVELS (Lw) — 524A072-300
UNIT
CFM
dB(A)
524A072
2,400
86.3
524A090
3,000
88.3
524A120
4,000
91.6
524A150
5,000
91.1
524A180
6,000
92.7
524A240
8,000
96.4
524A300
10,000
96.2
NOTE: Since this data is calculated, these sound power levels may be different than the actual
sound power levels. The accoustic center of the unit is located at geometric center of the unit.
SYSTEM†
Net Cap.
EER
IPLV
(Btuh)
69,000
11.0
N/A
72,000
11.2
N/A
71,000
10.8
N/A
74,000
11.0
N/A
87,000
10.6
N/A
91,000
11.3
N/A
90,000
10.6
N/A
94,000
11.2
N/A
118,000
10.3
N/A
125,000
10.4
N/A
123,000
10.4
N/A
130,000
10.4
N/A
114,000
10.3
13.1
119,000
10.3
13.6
118,000
10.4
14.1
125,000
10.3
14.5
113,000
10.3
11.7
118,000
10.5
12.4
118,000
10.5
12.8
124,000
10.9
13.2
138,000
10.4
12.7
144,000
10.6
13.0
144,000
10.6
11.6
146,000
10.8
13.1
135,000
9.7
9.9
143,000
10.2
10.3
145,000
10.5
10.9
153,000
11.1
11.5
152,000
10.8
11.0
161,000
11.3
11.5
176,000
9.8
12.3
182,000
9.7
12.1
184,000
9.8
12.2
196,000
10.0
12.5
176,000
10.0
10.4
185,000
10.3
10.8
187,000
10.2
10.5
198,000
10.6
10.9
194,000
10.1
10.2
204,000
10.4
10.4
244,000
9.5
11.8
243,000
9.6
9.8
242,000
9.6
9.9
252,000
9.7
9.9
OCTAVE BANDS
63
125
250
500
1000
43.8
61.4
66.2
70.8
73.8
58.5
67.3
71.3
75.4
77.2
63.7
67.6
72.5
77.0
80.4
52.5
66.1
75.1
75.4
78.3
93.0
86.0
83.0
80.0
93.0
86.0
83.0
80.0
83.5
81.5
88.5
86.5
85.5
90.9
86.1
83.1
84.0
90.9
86.1
83.4
84.5
90.9
86.1
83.8
84.5
OCTAVE BAND CENTER FREQUENCY
63
125
250
500
93.2
89.2
85.2
84.2
95.3
91.3
87.3
86.3
98.6
94.6
90.6
89.6
97.3
93.3
89.3
90.3
98.9
94.9
90.9
91.9
102.6
98.6
94.6
95.6
102.5
98.5
94.5
95.5
3
CONDENSING UNIT ONLY**
Gross Cap.
(Btuh)
72,000
100,000
133,000
124,000
123,000
150,000
158,000
198,000
204,000
248,000
259,000
2000
4000
8000
75.2
73.0
62.7
75.8
76.5
71.3
77.5
74.7
65.9
73.5
71.0
64.2
78.0
73.0
71.0
78.0
73.0
71.0
82.5
76.5
61.5
73.5
71.7
66.7
76.6
73.2
63.5
79.2
74.3
65.5
1000
2000
4000
80.2
78.2
74.2
82.3
80.3
76.3
85.6
83.6
79.6
84.3
82.3
78.3
85.9
83.9
79.9
89.6
87.6
83.6
89.5
87.5
83.5
EER
IPLV
12.4
N/A
12.7
N/A
12.4
N/A
12.0
16.5
12.3
16.0
12.1
15.8
12.5
15.1
11
14.9
11.9
13.9
10.5
13.9
11.2
13.1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

566e569d569f576cCbk-wa100Cbk-wa101

Table of Contents

Save Article as PDF