ELECTRICAL DATA

HIGH WALL UNIT
SIZE
9K
12K
9K
12K
18K
208/230--- 1--- 60
24K
30K
36K
LEGEND
FLA --- Full Load Amps

CONNECTION DIAGRAMS

CONNECTING CABLE
OUTDOOR TO INDOOR
GND
L
S
N
Indoor Unit
Indoor
Signal
Ground
Power Supply
High
115-1-60
Voltage
9K and 12K 115V Indoor Unit
Notes:
1. Do not use thermostat wire for any connection between indoor and outdoor units.
2. All connections between indoor and outdoor units must be as shown. The connections are sensitive to polarity and will result in a fault code.
Front Panel
9K and 12K 115V
L
N
S
Fig. 11 --- Control and Power Wiring on Indoor Unit
INSTALL ALL POWER, INTERCONNECTING
WIRING, AND PIPING TO INDOOR UNIT
1. Run interconnecting piping and wiring from outdoor unit to
indoor unit.
2. Run interconnecting cable through hole in wall (outside to
inside).
3. Lift indoor unit into position and route piping and drain
through hole in wall (inside to outside). Fit the
interconnecting wiring into back side of indoor unit.
4. Put upper claw at back of indoor unit on upper hook of
Mounting Plate, move indoor unit from side to side to see
that it is securely hooked.
Table 4—Electrical Data
INDOOR FAN
V--- Ph --- Hz
FLA
0.33
115--- 1--- 60
0.33
0.33
0.33
0.49
0.61
0.61
0.61
115-1-60
FIELD POWER SUPPLY
GND
L
N
S
L
Indoor
Power to
Main
Signal
Indoor Unit
Power Supply
High
115-1-60
115-1-60
Voltage
9K and 12K 115V Outdoor Unit
Fig. 10 --- Connection Diagrams
Electrical box
cover
9K to 36K 208/230V
L1 L2
S
A14352
HP
0.053
0.053
0.053
0.053
Refer to outdoor unit installation instructions –
0.067
0.16
0.16
0.16
CONNECTING CABLE
OUTDOOR TO INDOOR
L1 L2
GND
N
S
Indoor
Indoor Unit
Signal
Power Supply
Ground
High
208/230-1-60
Voltage
9K to 36K 230V Indoor Unit
5. Open front cover of indoor unit and remove field wiring
terminal block cover.
6. Pull interconnecting wire up from back of indoor unit and
position in close to the terminal block on indoor unit.
7. Push lower part of indoor unit up on wall, then move
indoor unit from side to side, up and down to check if it is
hooked securely (see Fig. 12).
Fig. 12 --- Indoor Unit Installation
8. Connect wiring from outdoor unit per connection diagram
(see Fig. 10 and Fig. 11).
9. Replace field wiring cover and close front cover of indoor unit.
10. Piping:
a. Cut the pipe, with a pipe cutter, at 90 degrees (see Fig. 13).
b. Remove the service connection, if provided with the unit.
7
MAX FUSE CB AMP
Indoor Unit powered from the outdoor unit
208/230-1-60
FIELD POWER SUPPLY
L1 L2
S
Power to
Indoor
Indoor Unit
Signal
High
208/230-1-60
Voltage
9K to 36K 230V Outdoor Unit
Upper hook
Lower hook
GND
L1
L2
Main
Power Supply
208/230-1-60
A150732
A07347a