sauter TC 1250-0.1F Instruction Manual

sauter TC 1250-0.1F Instruction Manual

Digital coating thickness gauge

Advertisement

Quick Links

Instruction Manual Digital Coating
Thickness Gauge
SAUTER TC
Version 2.0
04/2020
GB
Sauter GmbH
Ziegelei 1
D-72336 Balingen
e-mail: info@kern-sohn.com
PROFESSIONAL MEASURING
Phone : +49-[0]7433- 9933-0
Fax: +49-[0]7433-9933-149
Internet: www.sauter.eu
TC-BA-e-2020

Advertisement

Table of Contents
loading

Summary of Contents for sauter TC 1250-0.1F

  • Page 1 Sauter GmbH Ziegelei 1 Phone : +49-[0]7433- 9933-0 D-72336 Balingen Fax: +49-[0]7433-9933-149 e-mail: info@kern-sohn.com Internet: www.sauter.eu Instruction Manual Digital Coating Thickness Gauge SAUTER TC Version 2.0 04/2020 PROFESSIONAL MEASURING TC-BA-e-2020...
  • Page 2: Table Of Contents

    Instruction Manual Digital Coating Thickness Gauge Thank you for purchasing a digital coating thickness gauge from SAUTER. We hope you will be very satisfied with the high quality of this measuring device and its extensive functionality. For any questions, wishes and suggestions please do not hesitate to contact us.
  • Page 3: Introduction

    "Wide measuring range and high resolution " Can be connected to a PC for data transfer via RS 232 interface Cable and software are available as optional accessories (ATC-01). 3. Technical data TC 1250-0.1F TC 1250-0.1FN TC 1250-0.1N Display 4 digits, 10mm LCD display with backlight 0 to 1250 μm / 0 to 50 mil (standard)
  • Page 4 Resolution 0,1 µm (0 to 99,9 µm), 1 µm (over 100) 3 % of the measured value or Min ± 2,5 µm. Applies within the tolerance band of ± 100 µm Measurement around the typical measuring range if a two-point uncertainty calibration was also performed within this tolerance band...
  • Page 5: Description Of The Control Panel

    4. Description of the control panel Model TC-F and TC-N Model TC-FN (Combi Model) 4-11 4-10 4-10 4-1 Measuring probe: F, N, or FN Display Zero key Plus button Minus key On and Off button (multifunctional) µm/ mil Changeover key (shortcut key) Battery compartment / cover S/C measuring mode button (single/continuous) 4-10...
  • Page 6: Zero Adjustment

    d) In case of possible inaccuracies in the measurement result, it is recommended to adjust the measuring instrument before measurement, as described in chapter 6. e) On the one hand, the device can be switched off with the on/off button 4-6. Otherwise, it switches itself off 80 seconds after the last key is pressed.
  • Page 7: Adjusting Foils

    a) When the battery symbol ``+/-`` appears on the display, the batteries should be replaced. b) The battery cover 4-8 is removed from the meter and the batteries are removed. c) The batteries (4x1.5 V AAA/UM-4) are inserted by observing the polarity when inserting them.
  • Page 8: 11. Notes

    11. Notes With the LN function, the linearization of the measuring instrument specified by the calibration can be changed. However, it is strongly recommended not to make any changes to the LN value, as this change will lead to deviating measurement results. Any change in the Ln value can significantly affect the measuring accuracy.

This manual is also suitable for:

Tc 1250-0.1fnTc 1250-0.1n

Table of Contents