NFX150-S1 Network Services Platform Quick Start
To mount the device on a rack:
Attach the ESD grounding strap to your bare wrist and to a site ESD point.
1.
NOTE:
If you are mounting multiple units in the rack, mount the heaviest unit at the bottom and mount the others
from bottom to top in order of decreasing weight.
Place the rack in its permanent location, allowing adequate clearance for airflow and maintenance, and secure it to the building
2.
structure.
Figure 1: Mounting the Device on Two Posts in a Rack
Align the mounting brackets along the front or rear of the side panels of the chassis— depending on whether you will front-mount
3.
or rear-mount the device—and attach the mounting brackets to the chassis by using the mounting screws. Tighten the screws.
Have one person grasp both sides of the device, lift the device, and position it in the rack, aligning the mounting bracket holes
4.
with the threaded holes in the rack rail. Align the bottom hole in each mounting bracket with a hole in each rack rail, making
sure that the level of the chassis is in alignment.
Have the second person use the mounting screws (and cage nuts and washers if your rack requires them) to screw the mounting
5.
bracket to the rack.

Connect Power to the Device

NOTE:
We recommend grounding for AC-powered systems. An AC-powered device gets additional grounding when
you connect the power supply in the device to a grounded AC power outlet by using the power cord. The NFX150
device uses a fixed, internal AC power supply.
To connect power to the device:
Attach the grounding cable to earth ground and then to the chassis grounding points.
1.
Set the power switch to the off (O) position.
2.
2