Microtube shaking incubator
Hide thumbs Also See for I-4001-HCS:

Advertisement

Quick Links

Labnet Microtube Shaking Incubator
Instruction Manual
Catalog Numbers:
I-4001-HCS
I-4002-HCS
This manual is available in additional languages at www.labnetlink.com.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the I-4001-HCS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Labnet I-4001-HCS

  • Page 1 Labnet Microtube Shaking Incubator Instruction Manual Catalog Numbers: I-4001-HCS I-4002-HCS This manual is available in additional languages at www.labnetlink.com.
  • Page 2: Table Of Contents

    Table of Contents 1.0 Introduction ................. . .1 2.0 Symbols and Conventions .
  • Page 3: Introduction

    Incubator are likely to be damaged, the rated safety level to be reduced, and the rated operation conditions to be affected. Labnet shall not be in any way responsible for the consequences resulting from operator’s not observing the following requirements.
  • Page 4 AC Power Line Considerations As an accessory of the Labnet Microtube Shaking Incubator, the AC power supply should be the default device. Once it is damaged, the AC power line may not be repaired, but must be replaced by a new one.
  • Page 5: Product Id Labels

    4.0 Product ID Labels For model I-4001-HCS  LABNET LABNET Model I-4001-HCS Model I-4001-HCS Power AC100-120V 50-60Hz 150W Power AC100-120V 50-60Hz 150W Name The Microtube Shaking Incubator Name The Microtube Shaking Incubator Fuse 125V 2.5A ( 5×20mm) SN *******-*** Date ****.**.** Fuse 125V 2.5A ( 5×20mm) SN...
  • Page 6: Specifications

    Operating conditions Transportation and storage -20°C to 55°C, relative humidity ≤ 80% conditions Electrical I-4001-HCS: AC100-120V, 50/60Hz, 150W I-4002-HCS: AC220-240V, 50/60Hz, 150W Dimension (L × W × H) 12.9 x 6.5 x 9.8 in. (328 × 166 × 249 mm) Weight 18.75 lbs.
  • Page 7: Operation Guide

    Temperature increasing indicator Actual temperature Constant temperature Set temperature indicator Actual vibration time Temperature decreasing indicator Set vibration time Timer indicator Actual vibration speed Vibration speed indicator Set vibration speed Button explanation Temperature set up buttons Temp Press to adjust the value ant set the requested temperature. Temp Keep pressing may help to speed up the setting time.
  • Page 8: Pulse Vibration

    If on the case high temperature point is set first and low TIME temperature is set after, then when performing the following actual calibration, please follow the order TEMP of low temperature first and high temperature after. TEMP TIME TIME LABNET MICROTUBE SHAKING INCUBATOR SPEED SPEED...
  • Page 9: Buzzer Set Up

    TEMP TIME SPEED TEMP TEMP TEMP TIME TIME TIME TEMP TIME Press both Temp and 30 minutes later, press When the calibration    Temp at the same time Short/Prog for one time, of 40°C is done, press to start the calibration. The and the display will show the Start/Stop to exit.
  • Page 10: Troubleshooting And Repair

    Should you have a question about the operation of the Labnet Microtube Shaking Incubator or if service is required, contact Customer Service. Do not send in a unit for service without first calling to obtain a repair authorization number.
  • Page 11: Spare Parts And Accessories

    10.0 Spare Parts and Accessories Spare Parts Cat. No. Description Quantity BYQ121L00000020 L socket head wrench BYQ900800000070 Cushioning balls for foot Fuse used for 230V model (250V, 1.5A Φ5x20 mm) BYQ15411A500170 Fuse used for 120V model (125V, 2.5A Φ5x20 mm) BYQ15412A000020 Accessories Cat.
  • Page 12: Limited Warranty

    Consequently, the buyer shall follow the instructions for reuse and recycling of waste electronic and electrical equipment (WEEE) provided with the products and available at www.corning.com/weee. LABNET MICROTUBE SHAKING INCUBATOR...
  • Page 13 To request certificates, please contact us at www.labnetlink.com. Warranty/Disclaimer: Unless otherwise specified, all products are for research use only. Not intended for use in diagnostic or therapeutic procedures. Corning Life Sciences makes no claims regarding the performance of these products for clinical or diagnostic applications. For additional product or technical information, visit www.corning.com/lifesciences or call 800.492.1110.