SKF LINCOLN 85831 Assembly Manual
SKF LINCOLN 85831 Assembly Manual

SKF LINCOLN 85831 Assembly Manual

Electric vent valve assembly for use with flowmaster ii ac electric pumps on drum cover 85757 120 lb. and 85758 400 lb. drum
Hide thumbs Also See for LINCOLN 85831:

Advertisement

Electric vent valve assembly
85831, 85832, 85833, 85834, 85835, 85836,
for use with FlowMaster II AC electric pumps on
drum cover 85757 120 lb. and 85758 400 lb. drum
December 2012
Date of issue
Form number
404475
Section
C8
Page
368A
D a n g e r
Read manual prior to installation or use
of this product. Keep manual nearby for
future reference. Failure to follow
instructions and safety precautions may
result in death or serious injury.
Assembly guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LINCOLN 85831 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SKF LINCOLN 85831

  • Page 1 Assembly guide Electric vent valve assembly 85831, 85832, 85833, 85834, 85835, 85836, for use with FlowMaster II AC electric pumps on drum cover 85757 120 lb. and 85758 400 lb. drum December 2012 Date of issue D a n g e r Form number 404475 Read manual prior to installation or use...
  • Page 2: Table Of Contents

    Contents Safety .................. 3 Use of this manual ..............3 Overview................3 General description and information ........3 Assembly ................4 Parts ................... 6 Lincoln industrial standard warranty ........9...
  • Page 3: Safety

    Use of this manual Safety Read and carefully observe these installation instructions before installing, operating or troubleshooting the assembly. The assembly Overview must be installed, maintained and repaired exclusively by persons familiar with the instructions. This manual details the procedure that must Install the assembly only after safety be followed while installing,the electric vent instructions and this guide have been read...
  • Page 4: Assembly

    Assembly 8 Refer to figure 1 and thread elbow (11) 2 Insert reducer nipple (17) into block valve into check assembly (9). (15) and tighten hand tight. Vent valve 3 Thread adapter (16) into block 1 Fasten pump to drum cover. End of procedure valve (15).
  • Page 5 Fig. 4 Insert hex head screws (19) through drum cover (24) or bracket (26) and into the solenoid vent valve (15). Tighten hex head screws (19). Refer to page 3, figure 1 and connect hose assembly (12) to both elbows (11). 10 Assemble hose assembly (10) to elbow (13) and to vent fitting (5).
  • Page 6: Parts

    Parts list Item no. Description Part no. Quantity Vent tube See below Hex nut, –14 12538 Gasket 31010 Hose assembly 272711 Vent fitting 272717 Safety unloader, 4,000 psi (275 bar) 272722 Male run tee, NPTF 276370 Adapter 12213 Check assembly 81938 Hose assembly 270726...
  • Page 7 Fig. IPB 1...
  • Page 8 Fig. IPB 2...
  • Page 9: Lincoln Industrial Standard Warranty

    Lincoln industrial This warranty gives you specific legal standard warranty rights. You may also have other rights that vary by jurisdiction. Customers not located in the Western Standard limited warranty Hemisphere or East Asia: Please contact Lincoln warrants the equipment manufac- Lincoln GmbH and Co.
  • Page 10 SKF brings innovative solutions to OEMs and production facilities in every major industry world- wide. These five competence areas include bearings and units, seals, lubrication systems, mechatronics (combining mechanics and electronics into intelligent systems), and a wide range of services, from 3-D...

This manual is also suitable for:

Lincoln 85832Lincoln 85833Lincoln 85834Lincoln 85835

Table of Contents