Installation; Dimensions; Placement; Air Intake - Technibel LIBERTY300 Installation And Operating Instructions Manual

Domestic hot water heat pump
Table of Contents

Advertisement

2 - INSTALLATION

2.1 Dimensions

2.2 - Placement

2.2.1 - Air Intake

To be considered when choosing the final placement:
• ':+3 must not be installed outdoor
• ':+3 must be installed in a room outdoor from frost. Also, the temperature of the air taken in must
range between -5°C and 35°C. When the temperature is below -5°C or above 35°C, the water is no
longer heated by the heat pump, but by the electrical backup.
• inlate air must be clear of any pollution, and dust.
• The air taken in must not originate from a heated room.
• The device must not be placed in a room which risks explosion due to gases, vapours or dust and
must not intake air from rooms with the same risks.

2.2.2 - Positioning

• The floor must be able to support the weight of the device (weight of D.W.H.P when full = approx. 440kg)
• Position ':+3 and adjust the stands in such a way that it is level. A slight inclination to the right of
the device (1° max.) is acceptable.
Œ

Ž








˜
š
Installation in a roo
s aller than 20 ² requires
ducts to take air in and to
Œ
œ
š

ž
š
˜
Ÿ
œ
˜
ž
š
 
¡
View from above
blown air out
 