LIBERTY300
DomEsTIc hoT waTER hEaT pump
user guide
LIBERTY300 works in priority with the heat pump, as long as air temperature sucked
in is higher than -5°C and less than 35°C.
The electric back up only runs when:
- air temperature is out of the nominal range
- water temperature is below 38°C and comfort function is activated
- Boost function is manually activated.
Taking into account the domestic hot water consumption, and in the aim of savings,
it is advised to set the water temperature at 50°C.
Check periodically there is no alarm message. In case of alarm, see error code
table.
1 - Controls
Menu button
Start / Stop
Clock settings
signification of symbols :
.........Compressor activated
......Ventilation activated
(speed 1 or 2)
...........Defrosting
...........Electrical backup activated
The information within this document is not contractual, we reserve the right to modify without warning the technical characteristics and the equipment of all appliances.
Screen
........Need for sanitary hot water
..........Econo-mode activated
(by time programming or external
activation)
..........Vacation mode activated
Ref. : 10-11-560 F 00
made in
FRaNcE
Fig. 23
Dial
Need help?
Do you have a question about the LIBERTY300 and is the answer not in the manual?
Questions and answers
the display has the message "F REQ. DEF RO."
The message "F REQ. DEF RO." on a Technibel LIBERTY300 display means "Defrosting too frequently." It indicates that the heat pump has stopped because defrosting is occurring more often than normal.
This answer is automatically generated