LIBERTY300
solar
Domestic hot water
solar and heat pump
Installation and operating instructions
Made in France
Ref. 10.13.19.GB.04

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LIBERTY300 SOLAR and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Technibel LIBERTY300 SOLAR

  • Page 1 LIBERTY300 solar Domestic hot water solar and heat pump Installation and operating instructions Made in France Ref. 10.13.19.GB.04...
  • Page 2: Table Of Contents

    SOMMAIRE 1 RECOMMENDATIONS 1 RECOMMENDATIONS ........2 1.1 - Storage and transport ..............2 - The cover of this device must never be 2 DESCRIPTION ..........3 used for carrying or handling and is not 2.1 - Description ..................3 designed for this purpose. 2.1.1 - Operation principal of the solar / heat pump combined system ..
  • Page 3: Description

    3.1 - Dimensions 2.1 - Description 2.1.1 - Operation principal of the solar / heat pump combined system LIBERTY300 Solar • is composed of a hot water tank, a solar heat exchanger, components of the refrigerating circuit, the air circuit and of the water circuit, as well as all the control, settings and monitoring panels designed for automatic functioning.
  • Page 4: Positioning

    3.2.2 - Positioning 3.4 - Air duct sizing D.W.H.P The connection of must be done using insulated air ducts of a nominal diameter of 160mm. The piping can be connected either on the intake side, the blowing side or both. Example : (1) : Elbow 70°C –...
  • Page 5: Condensate Line Connections

    This is source of energy • Condensate run-o (see section “Condensate line connections”) losses and lack of hot water. The cycling DRAINING OF LIBERTY300 Solar loop must be insulated and the circulating The drain valve must be installed in the lower position of inlet...
  • Page 6: Electrical Connections

    • Remove the cover of the device by removing the screws (a) of the shell. by the lower belt. • LIBERTY300 Solar can also operate using • Remove the black cover of the electric box an internal timing program (see section “Time programming”).
  • Page 7: Ventilation Control

    4 SET UP AND USE Clock settings Screen Dial LIBERTY300 Solar functions mainly with sun heat recovery through the solar collector. The water tank is heated up to 65°C as long as solar collector is sun exposed. Signi cation of symbols : When solar energy is not available, the tank is heated via the air to water heat pump.
  • Page 8: Time Setting

    4.3 - Time setting “Clock settings”. • Direct access by pressing 26/-- /11 -- /09 /11 26/09 /11 17: 32 17: 32 17: 32 day setting month setting 26/09 /-- MONDAY 17: 32 -- : 32 year setting hour setting MONDAY Validates the new setting 17: --...
  • Page 9: Desired Temperature Setting

    During the entire 3 seconds until the screen displays “SETTING” duration of the vacation LIBERTY300 Solar will display “RETURN” (Parameter settings). (Return from vacation) along with a countdown for the number of days.
  • Page 10: Parameters Settings

    Menu = return to the screen “SETTINGS” press on Menu = return to the screen “INSTALLER” press on Menu = return to the main screen Speed setting 2 is mandatory when LIBERTY300 Solar is connected using air ducts - INSTALLATION GUIDE 10.13.19.GB.03 -...
  • Page 11: Par.07 Solar Set Point

    • Turn the dial to change the mode. Waiting for solar period • Press the dial to accept the changes During this period, LIBERTY300 Solar restricts the operation Example of heat pump to the upper half of the cylinder. To exit: 1 press on Menu = return to the screen “SETTINGS”...
  • Page 12: Resetting Parameters

    • Make the anode inspection every year the di erent information given by the sensors and input. • Do not spring water on electical parts DISPLAY • Press the dial to read the sensor values of LIBERTY300 Solar ¡ ¢ £ ¤...
  • Page 13: Anti-Corrosion Anode

    5.3 - Anti-corrosion anode • Lack of Hot water The anti-corrosion anode is installed in the hot water tank and must be regularly electrically tested as well as a minimum of every D.W.H.P. Verify that: years after the activation of Replace it if necessary.
  • Page 14: Error Codes

    5.6 - Error codes To reset error, press the dial one time 5.6.1 - Causes and solutions 'LVSOD\ 1DWXUH RI HUURU 3UREDEOH FDXVHV 6ROXWLRQ + 1,  ‡ 2YHU YROWDJH RQ HOHFWULFDO QHWZRUN 'HIHFWLYH HOHFWURQLF FDUG ‡ 5HSODFH SRZHU FDUG $/1.
  • Page 15: Functioning Of Liberty300 During Error

    5.6.2 - Functioning of Liberty300 during error €  ‚ ƒ „ … † † ‡ ˆ ‰ ˆ  ‘ ’ ALARM 00 Memory Tank stops EPRO ALARM 00 Screen Tank stops Sensor #1 defective t_air Heat pump stopped ; Electrical backup heats water to 43°C (min.38°C) (temperature of air taken in) Sensor #2 defective T_degiv...
  • Page 16: Part List

    5.7 - Part list Repère Référence Désignation % 8SSHU SODWH % 'LVSOD\  FDEOH % /RZHU SODWH 0DJQHVLXP DQRGH % % $TXDVWDW ƒ % (OHFWULF KHDWHU % (OHFWULF KHDWHU VHDO % 6HQVRU EORFNLQJ HOHPHQW 7HPSHUDWXUH VHQVRU PP % % 7HPSHUDWXUH VHQVRU PP % 7HPSHUDWXUH VHQVRU PP )ODQJH ZLWK VHDO...
  • Page 17: Warranty

    6.1.2.1 - Handling 6 WARRANTY Cases (non-limited) for voiding of warranty: • Diverse damages caused by shock or falling during handling after delivery from the factory. The warranty covers: • Deterioration of the device caused by handling which does not •...
  • Page 18: Appendix

    7 APPENDIX 7.1 - Characteristics /LEHUW\6RODU  (&662/7=%$ /LEHUW\6RODU  (&662/7=%$ /LEHUW\6RODU  (&662/7=%$ /LEHUW\6RODU  (&662/7=%$ &RQVWUXFWLRQ 6RODU KHDW H[FKDQJHU 6RODU IOXLG PD[ SUHVVXUH 03D  EDU +HDW H[FKDQJHU VXUIDFH DUHD Pò 6RODU KHDW H[FKDQJHU LQOHW FRQQHFWLRQ 0  6RODU KHDW H[FKDQJHU RXWOHW FRQQHFWLRQ 0  %RG\ FRYHU...
  • Page 19: Electrical Schematic

    7.2 - Electrical schematic LTS : High-temperature switch Compressor C1 : Start-up capacitor for compressor EV : Solenoid valve C2 : Ventilator 2 F capacitor RE : 1500W electrical heater C4 : Ventilator 4 F capacitor LTS : Security temperature limiter thermostat of the electrical heater 1M resistance for ventilator AqL : Limiter aquastat for the electrical heater...
  • Page 20: Cabling Schematic

    7.3 - Cabling schematic - INSTALLATION GUIDE 10.13.19.GB.03 -...
  • Page 21 LTS : High-temperature switch C1 : Start-up capacitor for compressor C2 : Ventilator 2 F capacitor C4 : Ventilator 4 F capacitor 1M resistance for ventilator RC : Compressor contactor Ventilator Compressor EV : Solenoid valve RE : 1500W electrical heater LTS : Security temperature limiter thermostat of the electrical heater AqL :...
  • Page 22: Performance Curves

    7.4 - Performance curves 7.5 - Maintenance log The performance is measured with a standard heating cycle with 15°C cold water. R134a is a greenhouse gas relevant to the 7.4.1 - C.O.P. Evolution Kyoto Protocol. All intervention on the refrigerating circuit must be done by a quali ed This curve represents the C.O.P.
  • Page 23 Recovered refrigerant Date Technician Nature of the operation Charged refrigerant - INSTALLATION GUIDE 10.13.19.GB.03 -...
  • Page 24 NOTES : Zone industrielle RD28 BP131 Reyrieux 01601 Trevoux Tél. (33) 4 74 00 92 92 Fax (33) 4 74 00 42 00 http://www.technibel.com B1871817 - 13.171-C...