2 - INSTALLATION
2.1 Dimensions
2.2 - Placement
2.2.1 - Air Intake
To be considered when choosing the final placement:
• D.W.H.P must not be installed outdoor
• D.W.H.P must be installed in a room outdoor from frost. Also, the temperature of the air taken in must
range between -5°C and 35°C. When the temperature is below -5°C or above 35°C, the water is no
longer heated by the heat pump, but by the electrical backup.
• inlate air must be clear of any pollution, and dust.
• The air taken in must not originate from a heated room.
• The device must not be placed in a room which risks explosion due to gases, vapours or dust and
must not intake air from rooms with the same risks.
2.2.2 - Positioning
• The floor must be able to support the weight of the device (weight of D.W.H.P when full = approx. 440kg)
• Position D.W.H.P and adjust the stands in such a way that it is level. A slight inclination to the right of
the device (1° max.) is acceptable.
View from above
Installation in a room
smaller than 20m² requires
ducts to take air in and to
blown air out