Troubleshooting - Titan TTB777VAC Manual

Wet/dry vacuum cleaner 1500 w
Table of Contents

Advertisement

Troubleshooting

Troubleshooting

Suspected malfunctions are often due to causes that the users can fix themselves.
Therefore check the product using this section. In most cases the problem can
be solved quickly.
WARNING! Only perform the steps described within these instructions!
All further inspection, maintenance and repair work must be performed
by an authorised service centre or a similarly qualified specialist if you
cannot solve the problem yourself!
Problem
1. Product does
not start
2. Product does
not reach full
power
3. The vacuum
will stop
picking up
dust/water
38
Possible Cause
1.1. Not connected to power
supply
1.2. Power cord or plug is
defective
1.3. Other electrical defect to
the product
2.1. Extension cord not
suitable for operation
with this product
2.2. Power source (e. g.
generator) has too low
voltage
2.3. Air vents / air inlet / air
outlet are blocked
2.4. Activated safety valve /
too much water in the
tank
3.1. Activated safety valve /
too much water in the
tank
TTB777VAC by TITAN
MWDV16L-A by MacAllister
Solution
1.1. Connect to power supply
1.2. Check by a specialist
electrician
1.3. Check by a specialist
electrician
2.1. Use a proper extension
cord
2.2. Connect to another
power source
2.3. Clean the air vents / air
inlet / air outlet
2.4. Drain excess of water
from the tank
3.1. Let the product cool down
and then drain excess of
water from the tank

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents