60/78
Installation
Bosch Rexroth AG, Control block SB24/34, RE 66170-B/2019-05-15
7.6.6
Customer-specific coupling connection
Item
Designation
Directional valve
Coupling housing
O-ring
Socket-head screw
The coupling connections are customer-specific and deviate from the illustration.
Installation of customer-specific coupling flange:
1.
Insert the O-rings
2.
Align coupling housing
3.
Align coupling housing
threads
in directional valve
4.
Tighten the coupling housing
coupling port
of directional valve
5.
Tighten socket-head screws
Use
Port A and B
into directional valve ports
with flange surface to the directional valve
and the mounting bores with the coupling mounting
.
with the four socket-head screws
.
. Tightening torque M
Information
Number
24.5 × 2.15
2
M6
4
and
.
.
at the
= 11
+1
Nm.
A