Graco Husky 2200 Operation page 21

Air-operated diaphragm pump
Hide thumbs Also See for Husky 2200:
Table of Contents

Advertisement

Overmolded
Overmolded Diaphragms
Overmolded
Operating Air
Air Pressure
Operating
Operating
Air
A A A
125 psi (0.86 MPa, 8.6 bar)
B B B
100 psi (0.7 MPa, 7.0 bar)
C C C
70 psi (0.48 MPa, 4.8 bar)
D D D
40 psi (0.28 MPa, 2.8 bar)
How
How to to to Read
How
Read the
Read
the
the Charts
1. Locate fluid flow rate along
bottom of chart.
2. Follow vertical line up to
intersection with selected
operating air pressure
curve.
3. Follow left to scale to read
fluid outlet
outlet pressure
pressure (top
fluid
fluid
outlet
pressure
chart) or air
air consumption
air
(bottom chart)
3A2578E
Tel: 866-777-6060
Fax: 866-777-6383
Diaphragms
Diaphragms
Pressure
Pressure
PSI
PSI
PSI
(MPa, bar)
(MPa,
(MPa,
bar)
bar)
Charts
Charts
consumption
consumption
scfm
scfm
scfm
(Nm
(Nm
(Nm
3 3 3
/min.)
/min.)
/min.)
Springer Pumps, LLC
Fluid
Fluid Pressure
Fluid
Approximate
Approximate
Approximate Cycles
31
125
(0.86, 8.6)
A
100
(0.70, 7.0)
B
75
(0.52, 5.2)
C
50
(0.34, 3.4)
D
25
(0.17, 1.7)
0
0
40
(151)
Fluid
Fluid
Fluid Flow
Flow — — — gpm
Flow
Air Consumption
Consumption
Air
Air
Consumption
Approximate
Approximate
Approximate Cycles
31
62
175
(5.0)
140
(4.0)
105
(3.0)
70
(2.0)
35
(1.0)
0
0
40
80
(151)
(303)
Fluid Flow
Flow — — — gpm
Fluid
Fluid
Flow
Performance Charts
Pressure
Pressure
Cycles per
Cycles
per Minute
per
Minute
Minute
62
93
124
80
120
160
(303)
(454)
(606)
gpm (lpm)
gpm
(lpm)
(lpm)
Cycles per
Cycles
per Minute
per
Minute
Minute
93
124
A
B
C
D
120
160
(454)
(606)
gpm (lpm)
(lpm)
gpm
(lpm)
Website: www.springerpumps.com
Int'l: +001 267 404 2910
155
200
(757)
155
200
(757)
21

Advertisement

Table of Contents
loading

Table of Contents