OPERATING INSTRUCTIONS
MY REMOTE?
When reinstalling batteries, the thermostat may have been
pressed while the batteries were changed. To make your
thermostat reappear, follow these steps:
1. Remove one battery.
2. Press and hold the thermostat button on the remote.
3. Reinstall the battery while holding the thermostat button
down.
4. If you see "set", the thermostat button is now enabled.
5. If you see "clear", the thermostat button is disabled.
6. Repeat this procedure if you did not see "set" or "clear"
to add/remove the thermostat option.
WHY WON'T IT TURN ON?
If your remote control is working, but your appliance won't
turn on, it may be in "lockout" mode. To reset a lockout
follow these steps:
1. Turn off remote.
2. Turn on remote and wait 2 seconds.
3. Turn off remote and wait 2 seconds.
4. Turn on remote and wait 2 seconds.
5. Turn off remote.
This should clear the lockout mode. Turn on the remote and
start the appliance. Ensure the master switch is in the "ON"
position. If the lockout mode is still on, follow these steps:
1. Turn off the remote.
2. If you see the snowflake icon, press the Mode button
and toggle it to IPI mode.
3. Shut off AC power to the ignition control module (shut
off breaker).
4. Toggle master switch to off. Wait 30 seconds.
5. Turn on AC power by turning on breaker.
6. Turn on remote, then turn off remote.
7. Toggle master switch back on.
8. Press Mode button on remote. Select CPI mode to
reignite the pilot. After pilot lights, turn on your remote
to ignite.
After completing these steps, contact your authorized dealer
if it won't turn on.

PRESSURE TESTING

NOTE: The fireplace and its main gas valve must be
disconnected from the gas supply piping system during any
pressure testing of the system at test pressures in excess of
1/2 psi (3.5 kPa).
PRESSURE CHECK TAPS FOR MANIFOLD (OUTGOING)
AND
INLET
(INCOMING)
INCORPORATED INTO THE VALVE. THE PRESSURE TAP
MARKED OUT MEASURES OUTGOING PRESSURE. THE
PRESSURE TAP MARKED IN MEASURES INCOMING
INLET PRESSURE TEST
NOTE: Make sure to apply these incoming pressure test
with all other gas fireplaces on, or at full capacity in the
house for proper pressure reading.
IF THE INLET PRESSURE READING IS TOO HIGH OR TOO
LOW, CONTACT THE GAS COMPANY. ONLY A QUALIFIED
GAS SERVICE TECHNICIAN SHOULD ADJUST INCOMING
1. Loosen the inlet (IN) pressure tap by turning screw
counterclockwise. See (A).
2. Attach manometer using a 1/4" (6 mm) I.D. hose. Light
pilot and burner. Check pressure to ensure it is between
the minimum and maximum recommended pressure
settings.
3. Turn off burner and pilot.
4. Disconnect hose and tighten the inlet (IN) pressure tap
by turning screw clockwise. Screw should be snug. Do
not over tighten.
5. Relight pilot and burner. Then reattach manometer to
the inlet pressure tap (A) to verify the tap is completely
sealed. Manometer should read no pressure.

MANIFOLD PRESSURE TEST

1. Light pilot.
2. Loosen manifold (OUT) pressure tap by turning screw
counter-clockwise (see (B).
3. Attach manometer to pressure tap using a 1/4" (6 mm)
I.D. hose.
4. Light burner. Check manometer reading.
5. Turn burner and pilot off.
37
CAUTION:
PRESSURE
HAVE
PRESSURE.
CAUTION:
GAS PRESSURE.
A
B
© 2021 Breckwell Hearth
BEEN

Advertisement