Displayed Symbols - Vitek VT-6400 BK Manual Instruction

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Current temperature on the given channel
Upper temperature limit (if this option is off, "OFF" is displayed): icon ▲is displayed
Lower temperature limit (if this option is off, "OFF" is displayed): icon ▼ is displayed
2. During indication of the temperature limits enlisted above pressing buttons
switching on/off the given temperature limit.
e) Setting temperature limits
1. In temperature and humidity mode press button ALARM/CHART to select sound warning for
which you want to set parameters.
2. Press and hold button ALARM/CHART until the value of temperature limit near the adequate icon
▲ or ▼ starts blinking.
. Setting extreme temperature values.
Use buttons
«+»/ «-» to set extreme temperature value. For fast alteration of input parameter
press and hold these buttons. Press button
4. After completion of input system returns to the mode of sound warning of temperature limits
overrun selection.
f)
Switching off sound warning in case temperature extreme values are set.
In order to switch off sound warning press button ALARM/CHART.
g) Viewing minimal/maximal value of temperature and humidity of given channel
In temperature and humidity mode on pressing MEM button systems switches between the next
parameters:
Current temperature and humidity measured by remote sensor
Minimal temperature and humidity measured by remote sensor
Maximal temperature and humidity measured by remote sensor
h) Minimal/maximal temperature values reset
In temperature and humidity mode press and hold button MEM to clear memory for all channels.
i)
Status of data receive from remote sensor
Icon
indicates status of data receive from remote sensor.

Displayed symbols:

Basic block is in data signal search mode
Temperature date are registered
Data signal from temperature remote sensor is
not received
j)
Basic block activation for searching for the signals from all remote sensors.
Basic block can be activated manually for receiving signals from all remote sensors. Press and
hold button «-» for activating signal search.
k) No data signal
If there is no remote sensor indications, press and hold button «-» for 2 seconds to start
searching of data signal from remote sensor. If signal search has no result, check out the next:
1. If remote sensor is in range of action. Shorten the distance between basic block and remote
sensor if necessary.
2. Replace batteries of temperature remote sensor.
6400IM.indd 7
ALARM/CHART
to confirm preset value.
7
ENGLISH
«+»/«-» leads to
23.01.2009 10:14:43

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vt-6400

Table of Contents