inlet valve stainless steel tube and stop at the second O-ring. Next, align and insert the inlet valve into
the main tube, as noted above. If this is done properly, the lever should lift up. If it does not, the valve
has not been aligned correctly.
4. Install the spring and balance spacer with O-ring into the
main tube. Make sure the balance spacer is properly aligned
inside the main tube by pushing in on the end of the spacer
and slightly turning it with your finger tip to see that it
moves inward (i.e., it engages the hole in the inlet valve).
5. Lightly lubricate the ends of the transfer pin and install into the end of the balance spacer. Thread the
flex knob assembly onto the end of the main tube (closest to the lever arms) until it just stops. Hand
tighten the assembly and then back the assembly out three turns.
© MMXV Kirby Morgan Dive Systems, Inc. All Rights Reserved
Fax: 805/928-0342
3. While holding the inlet valve in position, pinch each arm
of the lever and slowly remove the balance spacer and O-
rings. The inlet valve should remain in place. If it comes
out, repeat the process until the valve stays in place.