LV-7290 / LV-7295 / LV-7390/ LV-8225 Expand Serial Command Functional Specifications
9.9.5
CR_LAMPMSTS Command
Command
"CR_LAMPSTS"[CR]
Details
Get Lighting status of lamp
Acceptable
Response
Unacceptable
9.9.6
CR_PROJH Command
Command
"CR_PROJH"[CR]
Details
Get total running time of Projector by hour (h)
Acceptable
Response
Unacceptable
9.9.7
CR_HMLAMP Command
Command
"CR_HMLAMP"[CR]
Details
Get lamp number.
Acceptable
Response
Unacceptable
"000_%1"[CR]
"n**** " A number of * should be among 1-4.
First character shows how many lamps are incorporated in
projector. (1,2 or 4 )
Second character shows following status in order of lamp number.
"I"
Lamp is ON
"O" Lamp is OFF
%1
"X" Lamp failure
e.g.
"1I" ・・・・・・・ 1 lamp model and Lamp is ON
"2IO・・・・・・・ 2 lamps model and No.1 Lamp is ON and No.2Lamp
is OFF
"4IOXI" ・・・・ 4 lamps model and No.1,No.4 lamps are ON. No.2
lamp is OFF and No.3 model is failed.
"Error Code"[CR]
"000_%1"[CR]
%1
"0000000"~"0099999"
"Error Code"[CR]
"000_%1"[CR]
%1
"001"
"Error Code" [CR]