Westfalia Wetekom 82 67 24 Instruction Manual page 35

Digital clamp meter ac
Table of Contents

Advertisement

Available languages

Available languages

Measuring Procedure
1. Connect the black measuring cable to the COM input (4) and
then connect the red measuring cable to the V/Ω/
input (5).
2. Then set the rotary function switch (6) to the measuring range
.
3. Press the FUNC./HOLD key (2) until
display.
4. Connect the measuring cables to the component you intend to
check and read the value from the display.
Notes:
 Connect the red measuring cable to the anode (The end of the
diode not marked with a ring) and the black measuring cable
to the cathode.
 If a value of up to 3 V is displayed, the component is functional
in forward direction. The forward voltage is displayed. If the
overflow indicator "OL" is displayed, the diode is defective.
 Now turn the diode around (red + to the cathode and black - to
the anode). If the overflow indicator "OL" is displayed, the
diode correctly blocks. It is functional in reverse direction. If
the unit displays any voltage, the diode is defective.
Range
Operation
Resolution
1 mV
31
appears on the
Overload
protection
600 V
/