Table of Contents
loading

Summary of Contents for FAAC E844 3PH

  • Page 1 E844 3PH...
  • Page 2 Dieses Handbuch wurde 2020 veröffentlicht. Dieses Handbuch wurde 2020 veröffentlicht. © Copyright FAAC S.p.A. del 2020. Todos los derechos están reservados. © Copyright FAAC S.p.A. del 2020. Todos los derechos están reservados. No puede reproducirse, archivarse, distribuirse a terceros ni copiarse de No puede reproducirse, archivarse, distribuirse a terceros ni copiarse de ningún modo, ninguna parte de este manual, con medios mecánicos o...
  • Page 3: Table Of Contents

    6.1 Programming ........11  1 Technical data E844 3PH ......5 6.2 Operating logics .
  • Page 4: Eu Declaration Of Conformity

    E844 3PH will be installed, prior to commissioning the machine. These activities include the analysis of all the risks associated with the machine and subsequent implementation of all safety measures intended to fulfil the essential safety requirements.
  • Page 5: Meaning Of The Symbols Used

    RISK OF IMPACT/CRUSHING/SHEARING - Risk of  impact, crushing or shearing due to moving parts § CHAPTER/SECTION E.g.: §1.1 see section 1.1.  LED off  LED on   LED flashing  LED flashing quickly E844 3PH 532315 - Rev.B...
  • Page 6: Safety Recommendations

    Always wear the personal protective equipment rec- ommended for the type of activity to be carried out. The required level of workplace lighting must be equal to at least 200 lux. E844 3PH 532315 - Rev.B...
  • Page 7: E844 3Ph

     1 FAAC S.p.A. Power supply voltage • 380-415 V~ 3PH + N - It is prohibited to use the E844 3PH in the presence • 220-240 V~ 3PH of faults which could compromise safety. 50/60 Hz - Do not allow water jets of any type or size to come Max power into direct contact with the E844 3PH.
  • Page 8: Installation Requirements

    It is recommended to install a flashing light in a visible position to indicate when it is moving. The control accessories must be positioned in areas that are always accessible and not dangerous for the user. It is recommended to position the control acces- E844 3PH 532315 - Rev.B...
  • Page 9: Components

    Bus 2easy devices devices BUS MON Bus 2easy line Removable terminal board for connecting Bus 2easy CN10 devices Connector (5 pin) for FAAC radio/decoder boards Programming display F1 F2 F3 Mains power supply fuses (8AT) + - F Programming buttons E844 3PH 532315 - Rev.B...
  • Page 10: Connections

    So and/or Sc = nc and bridge with the common contacts (GND Activation must be intentional and the terminal), otherwise they would be active. gate must be visible E844 3PH 532315 - Rev.B...
  • Page 11: Accessories Power Supply

    +24V CN11 0.5 A max OUT 1 OUT 2 TEST OUT The E844 3PH supplies 24 V " and is short-circuit 1500 W max protected with a maximum current of 0.5 A for con- 230V~ 2EASY INPUT OPEN SX OPEN DX nected accessories.
  • Page 12: Bus 2Easy Devices

    It is a polarised type of connector. TEST OUT Connect the mains power supply using cables having If a FAAC model RP receiver is used, it is recommended a minimum diameter of 2.5 mm: to install the appropriate external antenna in order to obtain a sufficient range.
  • Page 13: Set-Up

    CLOSED limit switch must be engaged by the gate. 9. If the board is installed on gearmotor 844 R 3PH, regulate the obstacle detection sensitivity: func- tion EC in programming. 10. Complete the programming according to the required operating characteristics. E844 3PH 532315 - Rev.B...
  • Page 14 Courtesy Light 00...99 (available only for 844 R 3PH) no slowdown Cycle counter (x1000) 05...30 00...99 in steps of 1000 Partial opening width 01...20 in steps of 1 s E844 3PH 532315 - Rev.B...
  • Page 15: Operating Logics

    OPEN if the automation is closed, causes it to open. PRE-FLASHING and then CLOSES OPEN if the automation is open, causes it to close. OPEN during opening, stops it and the next OPEN command closes it. OPEN during closing, causes it to reopen. E844 3PH 532315 - Rev.B...
  • Page 16: Setup

    - Select the tl function in programming. - Press and hold down the + and - buttons simul- taneously, the gate starts to open and S1 appears on the display. - SETUP is complete when the open limit switch is reached. E844 3PH 532315 - Rev.B...
  • Page 17: Accessories

    If the sensitive edge is used to protect against a hazard, it must comply with standard EN 12978. ■ FailSafe The E844 3PH board has two inputs for connecting Failsafe is a functional test that is carried out before sensitive edges that are active during closing (SAFE a movement.
  • Page 18: Bus 2Easy Devices

    8.3 BUS 2EASY DEVICES than one pair of photocells with the same address, a It is possible to connect FAAC BUS 2easy devices (pho- conflict error is generated. tocells, sensitive edges, control devices) to this board. 2. Register the BUS 2easy photocells (see specific If no BUS 2easy accessories are used, leave connector section).
  • Page 19: Bus 2Easy Control Devices

    1 1 0 1 1 Open A_4 Open B_4 1 1 1 0 0 / 1 1 1 0 1 Open A_4 StopNC_2* 1 1 1 1 0 / 1 1 1 1 1 Open A_4 Close E844 3PH 532315 - Rev.B...
  • Page 20: Checking Bus 2Easy Devices

    OPEN A Total motion command active not active Opening limit switch not engaged engaged not engaged Closing limit switch engaged Bus 2easy devices See § BUS 2easy devices BUS MON Bus 2easy line E844 3PH 532315 - Rev.B...
  • Page 21: Maintenance

     8 lists the operations that should be performed Check that the maximum force required for manual move- on a regular basis on the E844 3PH board in order ment of the gate is below 225 N in residential areas and 390 to keep the automation working reliably and safely;...
  • Page 22 FAAC S.p.A. Soc. Unipersonale Via Calari, 10 - 40069 Zola Predosa BOLOGNA - ITALY Tel. +39 051 61724 - Fax +39 051 09 57 820 www.faac.it - www.faacgroup.com E844 3PH 532315 - Rev.B...