6. Wait for the tape to move back to the door after the test is complete.
7. Record the values for all rows and columns in the display.
8. The values returned are tape-type dependent and should appear as follows:
For AIT-1, the values should be less than 02.00 percent.
For AIT-2 and AIT-3, the values should be less than 04.00 percent.
Note:
If the results on any drive are higher than the percentage listed
above for your tape type, contact Spectra Logic Technical Support
at (800) 227-4637 or at (303) 449-0160, or send an e-mail to
support@spectralogic.com.
Library Confidence Test
1. Insert four bar-coded scratch tapes into the library.
2. From the Main screen, select Menu.
Spectra 10K Library Preventative Maintenance Guide