Federal regulations require all ceiling
fans with light kits manufactured or
imported after January 1, 2009, to
limit total wattage consumed by the
light kit to 190W. Therefore, this fan
is equipped with a wattage limiting
device.
Installation Guide
For Model:
DTB54EP5CM
E192641
net weight of fan: 23.37 lb. (10.6 kg)
READ THESE INSTRUCTIONS AND
SAVE THEM FOR FUTURE USE

Table of Contents:

Wiring. pg. 4 - 5
Warranty. pg. 9

Advertisement

Table of Contents
loading

Summary of Contents for Litex Industries DTB54EP5CM

  • Page 1: Table Of Contents

    190W. Therefore, this fan is equipped with a wattage limiting device. Installation Guide For Model: DTB54EP5CM Table of Contents: Safety Information. pg. 1 Package Contents. pg. 2 Preparation. pg. 3 Initial Installation. pg. 3 Normal Or Angle Style Fan Mounting.
  • Page 2: Safety Information

    SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, install or operate the product. If you have any questions regarding the product, please call customer service at 1-800-527-1292, 8:30 a.m.-5:00 p.m., CST, Monday-Friday. 1. Before you begin installing the fan, disconnect the power by removing fuses or turning off circuit breakers. CAUTION: Read all instructions and safety information before installing your new fan.
  • Page 3: Package Contents

    PACKAGE CONTENTS Part Description Quantity Downrod Canopy Mounting Bracket Motor Housing Yoke Cover Blade Blade Arm Switch Housing Plate 15 Watt Bulb Switch Housing Motor Screw (in motor) 3/16 Blade Screw (in hardware pack) 5.4M/M Lock Washer (in motor) Blade Washer (in hardware pack) E3 Wire Connector (in hardware pack) Blade Balancing Kit (in hardware pack) Canopy Mounting Screw...
  • Page 4: Preparation

    PREPARATION 1. Before beginning assembly and installation of product, make sure all parts are present. Compare parts with "Package Contents" list and diagrams on the previous page. If any part is missing or damaged, do not attempt to assemble, install or operate the product. Contact customer service for replacement parts as indicated at the bottom of page 2.
  • Page 5: Normal Or Angle Style Fan Mounting

    NORMAL OR ANGLE STYLE FAN MOUNTING 1. Insert downrod (A) through canopy (B), canopy cover (X) and yoke cover (E). (Note: Canopy cover (X) must be turned with the shiny side toward the motor housing (D). [Fig. 1] Thread wires from motor housing (D) through downrod (A).
  • Page 6: Final Installation

    WIRING (continued from previous page) FAN AND LIGHT CONTROLLED BY SEPARATE WALL SWITCHES. 1C. If you intend to control the fan and light with separate wall Fig. 1C switches, wire as indicated in the instructions in 1A except SWITCHED FAN POWER connect BLUE wire from fan to the BLACK supply from the SWITCHED WHITE (NEUTRAL)
  • Page 7 FINAL INSTALLATION (continued from previous page) 3. Position blade arm (G) under blade (F) and attach blade arm (G) to blade (F) with blade screws (L) and blade washers (N). Do not tighten blade screws (L) until each blade screw (L) has been started.
  • Page 8: Motor Housing Bulb Replacement

    FINAL INSTALLATION (continued from previous page) 9. Pull chain extensions (T) supplied in one of the hardware packs or custom pull chain extensions (not included) may be attached to fan and light pull chains. [Fig. 9] NOTE: This fan is remote control adaptable (remote control not included) Fig.
  • Page 9: Care And Maintenance

    CARE AND MAINTENANCE At least twice each year, lower canopy (B) to check downrod (A) assembly, and then tighten all screws on the fan. Clean motor housing (D) with only a soft brush or lint-free cloth to avoid scratching the finish. Clean blades (F) with a lint-free cloth.
  • Page 10: Warranty

    Contact Litex Customer Service at 1-800-527-1292 to arrange for return of fan. Return fan, shipping prepaid, to Litex Industries, Ltd. We will repair or ship you a replacement fan, and we will pay the return shipping cost.
  • Page 11 Por lo tanto, este ventilador tiene un aparato que sirve para limitar el vatiaje. Guía de instalación Para modelo: DTB54EP5CM Indice de materias: Información de seguridad. Pág. 1 Contenido de paquete. Pág. 2 Preparación. Pág. 3 Instalación inicial. Pág. 3 Estilo de montaje del ventilador normal o en ángulo.
  • Page 12 INFORMACION DE SEGURIDAD Por favor lea el instructivo entero antes de tratar de ensamblar, instalar o hacer funcionar el producto. Si tiene alguna pregunta acerca del producto, por favor llame al servicio al cliente al 1-800-527-1292, de 8:30 a.m. a 5:00 p.m., hora central, de lunes a viernes.
  • Page 13 CONTENIDO DEL PAQUETE Pieza Descripción Cantidad Vástago Cubierta Soporte de montaje Bastidor del motor Cubierta del yugo Paleta Brazo para la paleta Placa de la caja del interruptor Bombilla de 15 vatios Caja del interruptor Tornillo del motor (en el motor) Tornillo para la paleta 4,76 mm (en paquete de artículos de ferretería) Arandela de seguridad 5,4M/M...
  • Page 14 PREPARACION 1. Antes de empezar con el ensamblaje e instalación del producto, asegúrese de tener todas las piezas. Compare las piezas con la lista y los diagramas del "Contenido del paquete" en la página anterior. Si falta alguna pieza o se encuentra dañada, no trate de ensamblar, instalar o hacer funcionar el producto.
  • Page 15 ESTILO DE MONTAJE DEL VENTILADOR NORMAL O EN ANGULO 1. Introduzca el vástago (A) en la cubierta (B), decoración para la cubierta (X) y la cubierta del yugo (E). Nota: Se tiene que voltear la decoración para la cubierta (X) para que el lado brillante dé al bastidor del motor (D).
  • Page 16 CONEXION DE LOS CABLES (continúa de la página anterior) VENTILADOR Y LUZ CONTROLADOS POR 1C. Si usted piensa controlar la luz y el ventilador con INTERRUPTORES DE PARED INDEPENDIENTES. interruptores distintos, haga las conexiones según las Fig. 1C ENERGIA ELECTRICA DEL INTERRUPTOR AL VENTILADOR instrucciones en el 1A excepto conecte el cable AZUL del ENE RGIA BLANCO (NEUTRAL)
  • Page 17 INSTALACION FINAL (continúa de la página anterior) 3. Coloque el brazo para la paleta (G) debajo de la paleta (F) y asegure el brazo para la paleta (G) a la paleta (F) con tornillos para la paleta (L) y arandelas para la paleta (N). No apriete los tornillos para la paleta (L) hasta que se haya introducido cada tornillo para la paleta (L).
  • Page 18 INSTALACION FINAL (continúa de la página anterior) 9. Se pueden fijar las extensiones para las cadenas de encendido (T) provistas en uno de los paquetes de artículos de ferretería a las cadenas de encendido para el ventilador y la luz o usar extensiones para cadenas de encendido hechas a medida (no incluidas).
  • Page 19 CUIDADO Y MANTENIMIENTO Baje Ia cubierta (B) para inspeccionar el conjunto del vástago (A) por lo menos dos veces al año, y luego apriete todos los tornillos del ventilador. Limpie el bastidor del ventilador (D) solamente con un cepillo suave o un paño que no tenga pelusa para no rayar el acabado.
  • Page 20 Ni Litex Industries ni el fabricante se harán responsables por lo que pasa por una instalación inadecuada o el uso impropio de este producto. La compañía no se hará responsable en ningún caso de ningún daño emergente por incumplimiento de esta o cualquier otra garantía expresada o implicada en absoluto.

Table of Contents