Nortel Meridian 1 Manual page 89

Upgrade system installation through x11 release 21
Table of Contents

Advertisement

4-10
SL-1 ST and STE system upgrades
553-3001-250 Standard 14.00 August 1996
28 Press the RS button on the QUAA3 Power Unit to begin a sysload.
System messages similar to the following will appear:
SYS000
SYSLOAD RLS: xxISSUE:x
DONE
INI000
29 Log into the system.
30 Load the Equipment Data Dump Program (LD 43). At the prompt, enter
LD 43
Always enter LD 43 from the source (current) media. Do not exit LD 43.
When "EDD000" appears on the terminal, proceed to the next step.
31 Set the ENB/DIS switch on the NT9D34 EMSI card to DIS and remove
the card. Replace the QMM42 cartridge for release 15 software with the
QMM42 cartridge for release 18 software. Reinstall and enable the card.
32 Remove the disks containing release 15 software from the drives and
insert ED floppy disks with release 18 software into the SMDU drives.
Insert disk A in drive A and disk B in drive B.
33 Perform a data dump. At the prompt, enter
EDD
When "DATABASE BACKUP COMPLETE" or "DATADUMP
COMPLETE" appears on the terminal, proceed to the next step.
If the data dump is not successful, do not continue; contact your
technical support organization. A data dump problem must be
corrected before proceeding.
34 Shut down power to the system by switching the circuit breaker for the
power supply to OFF.
35 If equipped, disconnect the cable to the SDI port on the QPC687 CPU
card.
to load the program
to begin the data dump
CAUTION

Advertisement

Table of Contents
loading