Upgrading Core 1

1
Set the ENB/DIS switch to ENB on the CNI card in Core/Net 1.
2
Set the ENB/DIS switch to ENB on the IOP/CMDU card in Core/Net 1.
3
On the CP card in Core/Net 1, press and release the MAN RST button.
When SYS700 messages appear on the LCD display, set the
NORM/MAINT switch to NORM. Within 60 seconds, the LCD will
display the following messages, confirming the process:
RUNNING ROM OS
ENTERING CPU VOTE
Within 10 minutes, an HWI533 message from the CPSI (Core 0) or SDI
port indicates the Core 0 memory is shadowed to the Core 1 memory.
Wait until the memory synchronization is complete before continuing.
Note 1: At this point, Core 0 is still active and in maintenance mode.
Core 1 is the standby (inactive) side. The memories are shadowed
(synchronized), but the hard disks are not synchronized (redundancy is
disabled).
4
Set the NORM/MAINT switch to NORM on the CP card in Core/Net 0
and perform a redundancy sanity test:
LD 135
STAT CNI
STAT CPU
TEST CNI c s to test the CNI on the inactive side
Note: Testing the CNI cards may take up to 90 seconds for each test.
5
Test the inactive Core, then switch Cores and test the other side:
TEST CPU
SCPU
TEST CPU
Note: Testing the CP cards may take up to 90 seconds for each test.
Upgrade system installation Upgrading to Meridian 1 system options
Meridian 1 option 61 upgrades
to load the program
to get the status of all configured CNIs
to get the status of both Cores
to test the inactive CP card and CP-to-CP cable
to switch to Core 0
to test the inactive CP card and CP-to-CP cable
10-59