For greatest convenience, use the dedicated wood-fired stove
vacuum cleaner with a non-combustible container.

6.2. Periodic cleaning

Quite frequently, the pellets offered at the market and used do have
reduced quality parameters. This results in increased deposition of ash
and slag in the flue pipes, which in turn, must be inspected and cleaned
once every 1 - 2 tons of pellets burned.

6.3. Seasonal cleaning and preventive maintenance.

Apart from the operations, part of the daily and periodic cleaning, before the new heating
season, a complete and thorough cleaning and preventive maintenance of the stove and its
equipment would be required.
Cleaning must cover the entire flue gas evacuation route.
-
The chimney is to be cleaned along all of its length – from its highest part at the roof
to its lowest one – the special cleaning opening.
-
Metal flue pipes must always be disassembled and cleaned.
-
Dismount the cap under the ash pan by undoing the М5 nuts (Fig.6). The cavity below
the heated surfaces towards the flue gas fan inlet must be cleaned using the special ash
vacuum cleaner.
-
Upon assembly, if the seal is damaged it must be replaced or smeared with heat-
resistant silicon. It is very important that the cap will tightly seal the opening.
-
The hopper must be emptied of any pellets and along with the auger - cleaned from
any clogging of damp powder using ash vacuum cleaner.
-
Cleaning the Y-filter upstream of the circulation pump.
-
Cleaning the flue gas chamber above the firebox.
If you encounter any difficulties, you can turn to the servicing technician, committed to the
service maintenance of your stove.
-
Combustion air supply pipe must be inspected for lack of any obstructions (Fig.2,
pos.3);
-
At the end of each heating season the manufacturer recommends to have an
authorized company perform the preventive maintenance, as it is related to the safe and
trouble-free operation, and hence, to the reliability and warranty period validity. Apart from
the activities listed, the service technician must inspect the flue gas fan, the seals and
operation settings of the controller.
All activities related to the daily, periodic and seasonal preventive maintenance are to the
best interests and at the expense of the user.
Important: Since it is possible that the water pump may become congealed or living
organisms may settle in the suction pipe or flue gas fan, it is necessary to pay special
attention to these areas before use, after the summer season.