PRITY PLS Installation And Operation Manual

PRITY PLS Installation And Operation Manual

By means of hot air convection

Advertisement

Quick Links

P A S S P O R T
I N S T A L L A T I O N A N D
O P E R A T I O N M A N U A L
for pellet burning heating appliances
"PRITY"
by means of hot air convection
PLS, PLM
Manufacturer: "Prity 95" OOD, Bulgaria, Lyaskovets, Maksim Raykovich Street No. 33
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PLS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PRITY PLS

  • Page 1 O P E R A T I O N M A N U A L for pellet burning heating appliances "PRITY" by means of hot air convection PLS, PLM Manufacturer: "Prity 95" OOD, Bulgaria, Lyaskovets, Maksim Raykovich Street No. 33...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS DESCRIPTION ...................... 3 Delivery and unpacking ..................3 Operating principle....................3 2. Technical parameters of PRITY pellet fireplaces with hot air convection ..5 GENERAL SAFETY ....................5 Standards and legislation ..................6 Liability ........................6 INSTALLATION..................... 7 Fire safety clearances .....................
  • Page 3: Description

    DESCRIPTION Prity pellet fireplaces with hot air convection are designed to meet your requirements for comfort and uniform heating of your home. They function as a solid fuel appliance, connected to a dedicated chimney for disposal of flue gases. It is suitable for one room or two adjacent rooms, if air-exchange between them is possible.
  • Page 4 The flue gas fan sucks in the required amount of air for a quality combustion process through the heat exchangers and the firepot openings. The actual amount of air passing is continuously measured by a flow meter. The electronic control unit, using a system of sensors and software, compares the measured amount of incoming air with the pre-set one and makes any corrections required through the rpm control of the flue gas fan.
  • Page 5: Technical Parameters Of Prity Pellet Fireplaces With Hot Air Convection

    2. Technical parameters of PRITY pellet fireplaces with hot air convection T EC HN IC A L P A RA M ET ER S Rated heat output .. Р3 ….……………….. 8,0 kW. 5,1 kW. Reduced heat output …Р1 ….………………….. 2,3 kW.
  • Page 6: Standards And Legislation

     This appliance may not be used, cleaned and serviced by children less than 12 years old and individuals with reduced physical, sensory or mental capacities, or with insufficient experience and knowledge.  This appliance is not meant for plays or experiments. ...
  • Page 7: Installation

    INSTALLATION The proper and fault-free operation of the pellet fireplace requires proper installation and connection to the flue gas exhaust system. Initial setting up and commissioning in conformity with the pellets’ quality and the chimney draught, should be performed by a technician specialized for the respective work or representative of the manufacturer.
  • Page 8: Fresh Air Intake For The Combustion Process

    The elements and facilities used for discharging the flue gases must be in conformity with the existing standards. The pipe diameter may not be smaller than the one of the flue gas fan. Before connection, a revision of the smoke-discharge system must be performed by a specialist.
  • Page 9: Connection To The Electricity Mains

    Sufficient air must be provided, which is necessary to ensure the normal combustion process and clean surrounding atmosphere. Where the room has tightly fitted doors and windows, it is necessary to provide for external air inflow in the area behind the appliance, such as ventilation pipe in the wall with a grate, turned to the outside.
  • Page 10: Operation Of The Fireplace

    OPERATION OF THE FIREPLACE Preparation for initially Ignition For PLM models – mount the display to the fireplace body in accordance with the diagram and connect it to the cable coupler provided. Room temperature sensor must be outside the fireplace body to provide correct measurement.
  • Page 11: Ignition, Fire-Up And Shutting Down The Fireplace

    Each of the icons becomes active upon touch for user-friendly command execution. Icon / arrow / returns to the previous screen. Language switching Once the screen is unlocked, follow the path below: - password 5555 - – Save. Date and time setting 00 / 00 / 00 - date format is day/month/year.
  • Page 12 Stabilization of the combustion mode. Р1 , Р2, Degrees of heat output modulation. Р3 The operation process develops in several stages. Upon the "Start” command the fireplace begins with a cycle of intense air purging of the firebox, in order to guarantee the cleanliness of the firepot and checks the chimney passability.
  • Page 13 The values of the parameters in the respective modes are pre-programmed and tested but they are subject to adaptation, in accordance with the pellets’ quality and chimney specifics. Setting-up the temperature In case the pre-set temperature needs to be modified, select the icon showing a house Then, a menu appears for selection of day or night temperature, with option for modification:...
  • Page 14 Service settings Upon selection of the icon a new screen opens, which provides access to the menu for changing the factory settings. Setting-up the operation mode Operation mode Menu Pellets adjustment Air adjustment Heat output limit Operation mode There are three parameters you can adjust in the Operation mode: - Air adjustment - Pellets adjustment - Heat output limit...
  • Page 15 speed and using the powerful air stream cleans the ash off the grate for a pre-defined period. Clock/Timer Using Clock icon you can set the current actual time and the date. Using Timer icon you can set delayed start and/or stop of the system! Current values Menu Clock / Timer...
  • Page 16: Alarms

    The red clock shows that the fireplace works and its stopping is to be done at the time pre-set by the timer. Alarms Poor flue gas passability due to chimney blockage has been detected by the pressure switch for 20 seconds. This alarm is accompanied by an audible signal.
  • Page 17 No Fire Unsuccessful kindling Power Off Restarting the control unit Fire extinct Extinguished fire No Fan Fan failure On system restart this menu is deleted! Alarms...
  • Page 18: Cleaning And Maintenance

    CLEANING AND MAINTENANCE IMPORTANT! Insufficient cleaning can interfere with the starting up and the normal, efficient operation of the fireplace, and cause various emergency modes. Therefore, please, observe the cleaning and maintenance instructions, using safety gloves and personal protection equipment for these tasks. 6.1.
  • Page 19 The chimney is to be cleaned along all of its length – from its highest part at the roof to its lowest one – the special cleaning opening. Metal flue pipes must always be disassembled and cleaned. For PLS model - cleaning the entrance Deflector of the flue gas fan below the firebox floor.
  • Page 20: Maintenance Service Work

    For more information, please see the video instruction at: http://prity-bg.com/2019/01/31/почистване-на-пелетна-камина/ MAINTENANCE SERVICE WORK All dealers and installers of Prity pellet appliances are required to register the sale and the maintenance service works for each appliance using its factory number in the user service software at the manufacturer’s website: http://prity-bg.com/service/...
  • Page 21: Warranty Card

    WARRANTY TERMS IMPORTANT! The manufacturer guarantees the proper and fault-free operation of PRITY pellet fireplaces only if the requirements for installation and operation, commissioning and service maintenance have been observed by an authorised service technician. The warranty shall start running from the date of filling-in and stamping of the warranty card.
  • Page 22 For diagnostics and troubleshooting related to the operation of the appliance, please contact your installer and request him to fill in the warranty card and require registration of the malfunction in the user service software at the manufacturer’s site http://prity-bg.com/service/.
  • Page 23 The seller shall be held liable for any lack of conformity of the products, subject of the sale contract in accordance with the warranty under art. 112 – 115 of the Consumer Protection Act. Manufacturer: "Prity 95" OOD, Bulgaria, Lyaskovets, Maksim Raykovich Street No. www.prity-bg.com SERVICE NOTES …………………………………………………………………………………………………………………………...

This manual is also suitable for:

Plm

Table of Contents