windows, it is necessary to provide for external air inflow in the area behind the appliance,
such as ventilation pipe in the wall with a grate, turned to the outside. Direct connection of
the stove to an external suction pipe is not recommended.
Presence of any system that sucks out air is not recommended in the room where the
appliance is installed, and where one exists, forced delivery air-compensation device is
required.
4.4. Connection to the Water Heating System (WHS)
IMPORTANT! Connection of the stove to the WHS must only be done by a
licensed installer and in compliance with the operating legal provisions!
4.5. Connection to the electricity mains
The appliance must be connected to the electricity
mains according to the operating standards 230V 50Hz by
means of the power supply cable to a three-core Schuco-
type wall outlet with a transitional device for protection
against overvoltages /power surges/.
Connection to the protection neutral earthing must be
100% tested and verified in advance.
Usage of an additional combined device for
stabilization of voltage to a normal sinusoidal waveform
and its redundancy using deep-cycle battery is recommended.
Usage of devices with pulsed non-sinusoidal voltage is absolutely forbidden, because it
can cause damage.
For more information, ask your electrician or dealer.
4.6. Used pellets
PRITY PELLET STOVE
1. Cold water inlet stub pipe 1".
2. Combustion air inlet
3. Flue gas outlet to the chimney
4. Power supply 230V50Hz.
5. Hot water outlet stub pipe 1".
- 33 -
50mm.
80 /
100 mm.