Embraer EMB145 Operation Manual page 1307

Hide thumbs Also See for EMB145:
Table of Contents

Advertisement

GROUND SERVICING
EICAS
MESSAGE
ATA
or
CONDITION
Absence of
DME 2
distance
information
on the RMU
and on the
34
PFD and
MFD
(Transitory
condition of
Integrated
Navigation
Unit 2)
Page
6
1-12-60
AIRPLANE
OPERATIONS
MANUAL
LOCATION
(1) On RMU 2, push the DME
(2) Move the cursor of RMU 2 to the
(3) Do the test of frequency
(4) Do the self-test:
DME
Code
01
Copyright © by Embraer. Refer to cover page for details.
PROCEDURE
function key.
DME 2 window.
selection:
(a) Put the cursor on the selected
frequency code.
(b) Turn the dual concentric
knobs.
A frequency code can be set.
(a) Set the RMU 2 to the DME 2
window.
(b) Push and hold the RMU TST
function key.
On the RMU, the DME 2
window shows:
 TEST and DME TEST
(amber).
 TEST (amber) and DME
PASS (green), at the end of
the test cycle.
NOTE: A DME ERR (red) is the
indication that the selected DME
is defective.
TEMPORARY REVISION 41.1