EMERGENCY
INFORMATION
CONTROLS AND INDICATORS
REMOTE PANEL
1 - ELT ALERT light (red)
− Flashes when the ELT is transmitting.
2 - ELT SWITCH
MAN
- Activates the ELT.
AUTO - Allows the ELT to be automatically activated.
3 - AUTO TEST/RESET button
− When pressed allows the ELT to be checked.
NOTE: The ELT test must be performed only pressing the
AUTO TEST/RESET Button.
− During AUTO TEST/RESET function, the ELT alert light
illuminates during 2 seconds.
− If a failure is detected during the test, the ELT alert light flashes.
For confirmation repeat the operation. If the failure persists set
the ELT Switch on transmitter panel to OFF position and report
to the maintenance personnel.
− Reset function allows deactivating the ELT, after a manual or
automatic activation.
TRANSMITTER PANEL
1 - ELT ALERT LIGHT (red)
− Flashes when the ELT is transmitting.
2 - ELT SWITCH
MAN/RESET - Activates
AUTO
OFF
Page
1-10-20
AIRPLANE
OPERATIONS
MANUAL
deactivating the ELT after a automatic activation.
- Enables the remote control to automatic operation.
- Deactivates de ELT.
Code
2
02
the
ELT.
Reset
function
allows
REVISION 13