Carrier AquaEdge 19XR Controls Operation And Troubleshooting page 98

Two-stage high-efficiency semi-hermetic centrifugal liquid chillers with pic 5 controls
Table of Contents

Advertisement

OBJECT NAME
ALARMRST_alarm_1
ALARMRST_alarm_2
ALARMRST_alarm_3
ALARMRST_alarm_4
ALARMRST_alarm_5
CAPACTRL_cm_stat1
CAPACTRL_ctrl_wt
CAPACTRL_gv1_tgt
CAPACTRL_vfd_tgt
CFGSURGE_gv1_pful
CFGSURGE_gv1_pmin
CFGSURGE_sgl_hoff
CFGSURGE_sgl_loff
CFGSURGE_sgl_off
CFGSURGE_sgl_pro
CFGSURGE_sgl_shfh
CFGSURGE_sgl_shfl
CFGSURGE_sgl_spdf
CONF_OPT_hgbp_opt
CONF_OPT_hgbp_sel
CONNECT_bacena
CONNECT_bacunit
CONNECT_ident
CONNECT_network
GENUNIT_AMPS_P
GENUNIT_ch_state
GENUNIT_CHIL_OCC_rd
GENUNIT_CHIL_OCC_wr
GENUNIT_CHIL_S_S_rd
GENUNIT_CHIL_S_S_wr
GENUNIT_ctl_mode
GENUNIT_CTRL_PNT_rd
GENUNIT_CTRL_PNT_wr
GENUNIT_DEM_LIM_rd
GENUNIT_DEM_LIM_wr
GENUNIT_EMSTOP_rd
GENUNIT_EMSTOP_wr
GENUNIT_FC_START_rd
GENUNIT_FC_START_wr
GENUNIT_HC_SEL_rd
GENUNIT_HC_SEL_wr
GENUNIT_ice_occ
GENUNIT_KW_P
APPENDIX D — NETWORK CONFIGURATION (cont)
Table C — BACnet Object Table
OBJECT ID
AV:68
AV:69
AV:70
AV:71
AV:72
AV:76
AV:73
AV:74
AV:75
AV:96
AV:95
AV:99
AV:98
AV:97
AV:103
AV:100
AV:101
AV:102
AV:104
AV:105
BV:37
BV:38
AV:107
AV:106
AV:4
AV:7
BV:3
BV:42
BV:2
BV:40
AV:1
AV:3
AV:114
AV:6
AV:115
BV:4
BV:41
BV:7
BV:43
AV:2
AV:116
BV:6
AV:5
OPTION
READ/WRITE
RO
RO
RO
RO
RO
COV, IR
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
COV, IR
RO
RO
COV, IR
RO
CMD
RW
COV
RO
CMD
RW
COV, IR
RO
COV, IR
RO
CMD
RW
COV
RO
CMD
RW
COV
RO
CMD
RW
COV
RO
CMD
RW
COV
RO
CMD
RW
COV
RO
RO
98
DESCRIPTION
Jbus Current Alarm 1
Jbus Current Alarm 2
Jbus Current Alarm 3
Jbus Current Alarm 4
Jbus Current Alarm 5
Comp1 Run State Val
Controlled Water Temp
Target GV1 Pos
Target VFD Speed Per
IGV1 Full Load Position
IGV1 Minimum Position
Envelop Upper Deadband
Envelop Lower Deadband
Envelop Line Offset
Surge Profile Offset
Surge Line Shape Factor
Sound Line Shape Factor
Envelop Speed Factor
EC Valve Option
No=0, Cont.=1,
ON/OFF=2, mA=3
EC Selection
Disable=0, Surge=1
Low Load=2, Comb=3
BACnet Enable
BACnet Metric Unit
BACnet Identifier
Call Home Configuration
BACnet Network
Percent Load Current
Chiller Status Code
Network:Cmd Occupied
Network:Cmd Occupied
Network:Cmd Start/Stop
Network:Cmd Start/Stop
Control Mode
Local=0, Network=1
Remote=2, Local Sched=3
Control Point
Control Point
Actual Demand Limit
Actual Demand Limit
Emergency Stop
Emergency Stop
Start Free Cooling
Start Free Cooling
Cooling/Heating Select
Cooling/Heating Select
Ice Schedule Occupied
Motor Percent Kilowatts