Voltage Supply - Bosch Rexroth ctrlX CORE Manual

Table of Contents

Advertisement

24 / 38
Electric installation
Table 13: Pin assignment of the power connector XD10
Plug contact
Signal
1
24 V
2
0 V
10.5.3 24 V voltage supply
For the voltage supply, use a power supply unit as described in the following chapter:
External power supply unit on page 23
The GND (U
) is not grounded in the device!
L
Power supply unit
PE
Separable
connections
Fig. 12: Structure of the supply voltage
Control does not start in case of reverse input voltage
The feeding of 24 V at the XD10 connector is protected against polarity reversal. A polarity
reversal of U
and GND feeding does not damage the device. However, the control does not
L
start and the status display is not on.
Dimensioning the voltage supply
Observe the maximum currents when dimensioning the voltage supply. The operating voltage allowed
has to be applied directly to the device.
The voltage must also not be exceeded if:
there are variations in line voltage, e.g. caused by different loads of the mains
there are varying load states, such as short-circuit, normal load, lamp load or no load
Bosch Rexroth AG
Function
+24 V DC supply voltage (U
GND (U
) (ground supply voltage)
L
Overvoltage category I, 24 V
0 V
24 V
)
L
FE
R911405645, Edition 02
ctrlX CORE
⮫ Chapter 10.5.1

Hide quick links: