Bosch Rexroth ctrlX CORE Manual page 12

Table of Contents

Advertisement

12 / 38
Protection class acc. to DIN EN 60 529
Protection class acc. to DIN EN 61010-2-201
Overvoltage category acc. to IEC 60664-1
Contamination level acc. to EN 61010-1
Mechanical tests
Vibration resistance acc. to DIN EN 60068-2-6
Shock test acc. to DIN EN 60068-2-27
Broadband noise acc. to DIN EN 60068-2-64
Electrostatic discharge
ESD resistance acc. to DIN EN 61131-2
Test voltage
To avoid vibration, secure the cables at a short distance (< 20 cm).
NOTICE
NOTICE
NOTICE
This is a product that corresponds to the limit values of the emitted interference of class A
(industrial environments). This is a product that does not correspond to the limit values of the
emitted interference of class B (residential area and small enterprises.
When using the product in residential areas or small enterprises, the operator has to take
actions to prevent radio interferences (also refer to DIN EN 55022).
Bosch Rexroth AG
IP20
III
2
2, no condensation allowed
Oscillations, sinusoidal in all three axes
5 Hz - 8.4 Hz with 3.5 mm amplitude
8.4 Hz -150 Hz with 1 g peak acceleration
Shock stress: Shock resistance in all three axes,
11 ms semi-sinusoidal 15 g
5-20-150 Hz with 0.572 g, 5 h per axis
Criterion B
8 kV for air discharge
4 kV for contact discharge
Failure of the product due to contaminated air
The ambient air must not contain acids, alkaline solutions,
corrosive agents, salts, metal vapors and other electrically
conductive contaminants in high concentrations
The devices to be installed into the housing and installation
compartments must at least comply with the degree of pro-
tection IP 54 according to DIN EN 60529.
The device shall be provided in a suitable fire enclosure in
the end-use application.
Defective product due to gases jeopardizing functions
Due to the risk of corrosion, avoid sulphurous gases (e.g. sulphur
dioxide (SO
) and hydrogen sulphide (H
2
resistant against these gases.
Failure of the product due to overheating
To avoid overheating and to ensure a smooth operation of the
product, sufficient air has to circulate according to the minimum
distances specified, see
on page
18.
S)). The product is not
2
⮫ Chapter 10.2 Installation notes
R911405645, Edition 02