ITech IT-M3400 Series User Manual page 146

Bi-directional dc power supply
Hide thumbs Also See for IT-M3400 Series:
Table of Contents

Advertisement

OCP
OVP
OPP
Voltage programming
Voltage monitoring
Current programming
Current monitoring
Voltage range
OVP
UVP
Frequency
Max. current (rms)
DC Offset
Working temperature
Storage temperature
Noise
Measurement range
Measurement accuracy
Measurement resolution
Max. efficiency (Full-
load)
Communication interfaces
Size and weight
Net weight
External analog (optional)
AC parameters
Environment
External temperature measurement
Efficiency
Communication(Optional)
RS232/USB/RS485/CAN/LAN/GPIB/Analog
Mechanical parameters
Copyright © Itech Electronic Co., Ltd.
Technical Specification
-3.1A or 3.1A
610V
-410W or 410W
External 0V~10V is 0~600V
External 0V~10V is 0~600V
External -10V~10V is -3A~3A
External -10V~10V is -3A~3A
100VAC -240VAC
264VAC
90VAC
47Hz~63Hz
2Aac (AC220V)
-0.1A~+0.1A
0- 40 °C
-20- 70℃
60dB
-20℃——120℃
±1℃
0.1℃
88%
450mm*214mm*43.5mm
5kg
135