BFT MOOVI 30 Installation And User Manual page 18

Electromechanical control device for vehicular barriers
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 15
17.2) TABLE A: DIP SWITCH
DIP
Default
Definition
TCA- Automatic
DIP 1
ON
closing time.
DIP 2
ON
FCH- Photocells.
DIP 3
OFF
BLI - Block Pulses.
3P/4P - 3 steps or 4
DIP 4
OFF
steps.
DIP 5
OFF
CODE FIX - Fixed code.
RADIO LEARN -
DIP 6
OFF
Transmitter program-
ming.
SCA- Gate open light
DIP 7
OFF
or 2nd radio channel.
DIP 8
OFF
FAST CLOSE
18
- MOOVI 30-50 - ALPHA BOM
INSTALLATION MANUAL
Cross out
setting
Description
used
ON
Automatic closing ON.
OFF
Automatic closing OFF.
ON
Photocells active during closing only.
OFF
Photocells active during closing and opening.
ON
START commands not accepted during opening.
OFF
START commands accepted during opening.
ON
Switches to 3-step logic.
OFF
Switches to 4-step logic.
ON
Activates built-in receiver in fixed-code mode.
OFF
Activates built-in receiver in rolling-code mode.
ON
Enables wireless memorizing of transmitters (Sect. "Remote Programming").
Disables wireless memorizing of transmitters. Transmitters are memorized only by means of
OFF
manual programming.
ON
Activates relay output as 2nd radio channel.
OFF
Activates relay output in Gate open light mode.
ON
Closes barrier after the photocells are cleared before waiting for the set TCA to elapse.
OFF
Command not enabled.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Moovi 60

Table of Contents