Door
Door handle
Interior/exterior material
Casters
Insulation
Air circulation system
Temperature probe
Ambients
Intended for indoor use where ambient temperature does not exceed 86 F (30 C) and ambient relative humidity
does not exceed 60% RH.
Clearances
To ensure proper ventilation of the refrigeration system, the following clearances are required:
§ 16 inches (41cm) above the freezer
§ 2 inches (5cm) behind freezer
§ 9 inches (23cm) on the left side. If the ambient is <86 F (30 C), no side clearance is required.
Electrical specifications
§ 120 V, 60 Hz, 1 phase
§ Full load amps: 12FLA, 67 LRA compressor
§ Minimum circuit ampacity: 25A with max 60 ft. (18.2 m) wire run between receptacle and breaker using
minimum 12 AWG
§ Minimum voltage at compressor terminals: 97 Vac when energized
§ Maximum size of branch circuit overcurrent device: 20A dedicated circuit
Refrigeration specifications
Refrigerant R404a, 10.6 oz (300 g)
Detail drawing
76.75"
(195 cm)
29.75"
(76 cm)
4
Specifications
Standard features – all models
Solid, insulated, stainless steel
ADA-compliant, full length handle with integral lock
Heavy-duty, corrosion resistant stainless steel
(4) dual-wheel swiveling casters with toe locks
2.75" (7 cm) thick, CFC-free foam insulation throughout
Ducted air through back plenum openings (16 - PL, 12 - LB) with front face return
Stainless steel RTD (resistance temperature detectors). One at top on all models. One
at bottom on PL models
79.5"
(202 cm)
FZR20
30.5" (78 cm)
FZR25
36.5" (93 cm)
Required Clearances
1.0" (3 cm) or
2.0" (6 cm) if
outlet located
directly behind
freezer)
00981795R03 – REF20/25 LB, PL
16.0"
(41 cm)