MOUNTING ENCLOSURE GUIDELINES
Mounting enclosure dimensions when installed with Beefeater hanging bracket BA70HS
Separation panel
Gas bottle
venting slots
Enclosure construction
All materials used for the construction of the enclosure and
gas bottle compartment must be non-combustible.
A 40mm min. gap between the enclosure and rear wall
is required. This allows for venting of the gas bottle
compartment. Vents should also be positioned at the front
of the enclosure.
The cutout size specified above and below allow for a 20mm
gap between the back of the barbecue and benchtop. This
gap will help maintain air flow around the barbecue.
The cutout sizes specified above are for use with the
Beefeater hanging bracket BA70HS. This bracket is
purchased separately as an accessory.
The cutout sizes specified below are for when the product is
installed without hanging brackets.
The product rests directly onto its base.
Mounting enclosure dimensions when installed without hanging brackets
Separation panel
Gas bottle
venting slots
880mm 4 burner
1050mm 5 burner
Rear wall/splashback to be
non-combustible material
830mm 4 burner
1000mm 5 burner
Rear wall/splashback to be
non-combustible material
650mm min.
40mm
gap min.
Enclosure ventilation requirements
AS5601 ventilation requirements for 9kg cylinder storage are:
Where of sheet metal or similar impervious construction
there shall be ventilation openings at the top and bottom of
the enclosure or recess, each opening providing a free area
of at least 200cm
2
for every cylinder enclosed.
For LPG installations having enclosed cabinetry below the
separation panel that does not contain a gas bottle, low
level venting must be installed. This is to allow the gas
which is heavier than air to escape from the enclosure in
the situation where there may be a leak.
A minimum opening of 200cm
650mm min.
40mm
gap min.
MOUNTING ENCLOSURE GUIDELINES
604mm
Gas bottle
venting slots
2
is required.
604mm
Gas bottle
venting slots
9