[SOURce:]VOLTage[:LEVel]:LIMit:LOW <NRf+>
This command sets the minimum setting voltage limit of the power supply.
Syntax
[SOURce:]VOLTage[:LEVel]:LIMit:LOW <NRf+>
Arguments
<NRf+> MIN TO MAX
Default value
MIN
Example
VOLT:LIM:LOW 0.00
Query command
[SOURce:]VOLTage[:LEVel]:LIMit:LOW? [MINimum|MAXimum]
Returns
<NR3>
[SOURce:]POWer[:LEVel][:IMMediate][:AMPLitude]
<NRf+>
This command sets the maximum power value of the power supply. The query
form of this command gets the power value of the power supply.
Syntax
[SOURce:]POWer[:LEVel][:IMMediate][:AMPLitude] <NRf+>
Arguments
<NRf+> MIN TO MAX
Default value
MAX
Example
POW 860.0
Query command
[SOURce:]POWer[:LEVel][:IMMediate][:AMPLitude]? [MINimum|MAXimum]
Returns
NR3