[Source:]Function:priority <Voltage|Current; [Source:]Apply <Nrf+>,<Nrf - ITech IT-M3200 Programming Manual

Programmable dc power supply
Table of Contents

Advertisement

[SOURce:]FUNCtion:PRIority <VOLTage|CURRent>
This command sets the priority mode of the power supply.
Syntax
[SOURce:]FUNCtion:PRIority <VOLTage|CURRent>
Arguments
<VOLTage|CURRent>
Default value
VOLTage
Example
FUNC:PRI VOLT
Query command
[SOURce:]FUNCtion:PRIority?
Returns
VOLTage|CURRent
[SOURce:]APPLy <NRf+>,<NRf+>
This command sets voltage and current values with a single command
message
Syntax
[SOURce:]APPLy <NRf+>,<NRf+>
Arguments
<NRf+> voltage value MIN TO MAX
<NRf+> current value MIN TO MAX
Default value
MIN,MAX
Example
APPL 10.00,3.500
Query command
[SOURce:]APPLy?
Returns
NR3,NR3
Copyright © Itech Electronic Co., Ltd.