CDVI Digicode DGA Installation Manual page 4

Illuminated mullion weatherproof keypad self contained
Hide thumbs Also See for Digicode DGA:
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION MANUAL
DGA
Cast aluminium Digicode
Self Contained
®
- the green LED lights on during 1 second to confirm programming of the code length.
3] Enter A5 to modify the master code:
- the green LED lights on during 1 second,
- enter the new 4 or 5 or 6-digit master code,
- the green LED lights on during 1 second to confirm programming of the new master code.
4] Press B to exit from programming mode:
- the red LED lights off to confirm exit from programming.
The red LED flashes 4 times to indicate a data computing error
Master code or user code: 12369
When changing to 4-digit code: enter 2369
When changing to 6-digit code: enter 012369
It is recommended to program the codes in 6-digits
and then modify the code length.
CHANGING THE MASTER CODE
1] Enter the master code twice (12345 default value master code):
- the red LED lights to confirm entry in programming mode.
2] Press A5:
- the green LED lights on during 1 second,
- enter the new master code (according to the code length set up),
- the green LED lights on during 1 second to confirm programming.
3] Press B to exit from programming mode. The red LED lights off to confirm exit from programming.
ADDING USER CODES
Group 1: from user number 00 to user number 59, relay 1
Group 2: from user number 60 to user number 99, relay 2
1] Enter the master code twice (12345 default master code):
- the red LED lights on to confirm entry in programming mode.
- pour programmer des codes :
MASTER CODE
MASTER CODE
2] To add a user code, enter the user number (from 00 to 99):
- If the user number is free, the green LED lights during 1 second enter the 4, 5 or 6-digit code,
- If the user number is already programmed, the red LED flashes 4 times,
- To modify the user code enter a 4, 5 or 6 digit code,
- To cancel the user code enter 000000 or 00000 or 0000 code,
4
cdvigroup.com
RED LED
LIGHTS ON
INSTALLATION MANUAL
EN
DGA
Cast aluminium Digicode
- The green LED lights on duri ng 1 second to confirm programming.
If the user code is already programmed or is identical to the master code, then the red LED
flashes 4 times to indicates a data computing error. Note that the codes 000000 or 00000
or 0000 are strictly used to deleted a user code only.
3] Press B to exit from programming mode. The red LED lights off to confirm exit from programming.
USER CODE LIST
00
25
01
26
02
27
03
28
04
29
05
30
06
31
07
32
08
33
09
34
10
35
11
36
12
37
13
38
14
39
15
40
16
41
17
42
18
43
19
44
20
45
21
46
22
47
23
48
24
49
SETTING ILLUMINATION AND OUTPUT TIME
1] Enter the master code twice (12345 default value master code):
- the red LED lights on to confirm entry in programming mode
2] Press A0 to program the key-in keypad time and the illumination time:
Self Contained
®
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
EN
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
5
cdvigroup.com

Advertisement

Table of Contents
loading

Table of Contents