(3)
Disconnect the eight connectors from the PCB. (Three connectors have already
been disconnected when removing the scanner unit.)
Panel Sensor
PCB ASSY
10
9
8
7
Main frame
Note:
When re-assembling, the cable connectors must be inserted securely into the PCB
connectors and the PCB must not be stressed by the harnesses.
The connectors should be inserted by matching the housing color and the number of
pins.
3.11
Low-voltage Power Supply PCB ASSY
(1)
Remove the one M4x12 tapping screw securing the low-voltage power supply PCB
ASSY.
(2)
Disconnect the two connectors for the heater harness and the LV harness from the
PCB.
Low-voltage Power Supply ASSY
1
2
3
5
4
6
Fig. 3-19
LV harness
Fig. 3-20
III-12
(Name of the Harnesses)
1. Low-voltage harness
2. Erase lamp harness
3. Toner harness
4. Scan motor flat cable
5. Laser harness
6. Solenoid harness
7. Main / sub motor connector
8. Fan motor 1 harness
9. Fan motor 2 harness
10. High-voltage flat cable
H
r h rn