I-3
Completely blank
Possible cause
Step
Developing bias
1
contact failure
Drum unit
2
Drum unit failure
3
Scanner harness
4
connection failure
Main / Panel
5
sensor PCB
connection failure
Scanner unit
6
failure
Check
Are the developing bias
contacts between the printer
body and drum unit dirty?
Are the drum shaft and drum
electrode of the printer body
connected correctly?
Is the problem solved after the
drum unit is replaced?
Is the scanner harness
connected securely?
Is there any play in the
connection?
Are printing signals being input
to the scanner?
Is the problem solved after the
main PCB or the panel sensor
PCB replaced?
Scanner interlock lever
damaged.
Scanner mirror is broken or
loose.
IV-7
Result
Remedy
Yes
Clean the electrodes
at both sides.
Yes
Clean the shaft and
the electrode.
No
Check the connection
between the shaft and
the electrode.
Yes
Replace the drum
unit.
No
Reconnect the
connector properly.
Yes
Replace the main
PCB or the panel
sensor PCB.
Yes
Replace the scanner
unit.
No
Replace the high-
voltage power supply
PCB.
HV.GND
contacts
(Fig.4-5)