4. INSTALLATION REQUIREMENTS

Installation and setup of the unit should be undertaken by a qualified professional. Room
or area where the unit is to be installed must meet workplace standards of local building code.
The unit must not be operated in outdoor environments. Do not expose to weather
conditions (rain, temperature fluctuations, proximity of heating equipment, direct sunlight etc).
Air at workplace should be free of corrosive vapors, airborne dust, and fibrous matter.
To provide access to the unit for maintenance and repair purposes, respect the following
clearances between the unit and building structures: 500 mm to the left or right, 200 mm above.
Electrical connections must comply with local electrical code. Make sure to follow
applicable grounding and insulation rules.
Supply, drain, and delivery pipework must comply with local plumbing code and have
sufficient flow capacity. Drain line of the unit must be separated from floor drain with an air gap.
Construction material or inside lining of permeate tank must be resistant to water
corrosion (e. g. stainless steel, polypropylene). Tank should be installed next to the unit.
Antiscalant pump suction line length should not exceed 1.5 m. Refer to dosing pump's
manual to adjust pump's settings if it has not been factory configured.

5. OPERATING REQUIREMENTS

5.1
Operator of the unit must strictly follow these guidelines and general electrical safety
precautions.
If power supply cable or any other electrical wiring is damaged, it must be replaced by a
vendor's service staff or similarly qualified person.
5.2
When operating the unit, ensure that pressure and flow rates are within specification
limits and that power supply is clean and uninterrupted.
5.3
Perform the following at least once a month:
• verify that pressure and flow rate parameters have not deviated (substantially);
• verify tightness (absence of leaks) from connections and visual integrity of parts.
5.4
In order to monitor performance of the RO machine, regularly keep record of
operation and write down parameter readings. Use membrane manufacturer's software tools for
normalization to control for fluctuations of pressure, temperature, and other operating conditions.
5.5
Change polypropylene cartridge when it has clogged. Pressure drop of 0.1 MPa or greater
on the sediment filter indicates that filter cartridge needs to be replaced as soon as possible.
This manual is the intellectual property of Ecosoft. Copying and reprinting is prohibited. © 2021