2.2. TECHNICAL SPECIFICATIONS

Table 1. Physical parameters
Model (SKU)
Rated capacity, LPH*
Membranes
Power consumption
Dimensions (Width × Depth × Heigth)
Approximate dry weight
Port sizes (feed water inlet, permeate
outlet, concentrate drain outlet)
Working flow rates in typical operating conditions**
Recycle flow rate
Drain flow rate
Permeate flow rate
Water consumption per forward flush
* at feed water temperature = 25⁰С, TDS=10 g/l, 40% permeate recovery
** feed water must comply with requirements in Table 2. See Installation and Startup section
for a more specific instruction on Permeate, Drain, and Recycle flow rates.
Table 2. Limitations
Influent water quality ***
150 mg/l CaCO
Max. Total
(without anti-
Hardness
scalant)
20 mg/l
Max. Silica
(without anti-
scalant)
Max. Total Sis-
10 000 mg/l
solved Solids
Operating parameters
Required supply
0.2...0.4 MPa
water pressure
Temperature of
5...30 °C
water
***Some limitations may not apply if using antiscalant, oxygen scavenger, or
other type of chemical pretreatment.
This manual is the intellectual property of Ecosoft. Copying and reprinting is prohibited. © 2021
MO6500BWTSS
280
1 × 4040
0.75 × 0.54 × 1.52 m
130 kg
500...1000 l/h
150...300 l/h
250...400 l/h
Max. Iron,
3
Manganese, Hy-
0.05 mg/l
drogen Sulfide
Max. Chemical
Oxygen Demand
5.0 mg/l O
(KMnO
)
4
Max. Chlorine
0.1 mg/l
(continuous)
Max. operating
2.5 MPa
pressure
230 V, 50 Hz
Electrical power
(1 phase)
INSTRUCTION MANUAL ECOSOFT RO SYSTEM MO6500BWTSS
MO12000BWTSS
500
2 × 4040
2.2 kW
150 kg
½"
500...1000 l/h
250...500 l/h
450...700 l/h
40...60 l
RO system. Well water may contain
impurities such as hardness, iron,
manganese, silica, hydrogen sulfide
that can quickly lead to membrane
2
failure. Some of these challenges
can be addressed by using injection
of antiscalant. Perform a detailed
laboratory analysis of your well
water and consult a water treatment
specialist to see if you need additional
equipment for treating your well water.
Tap feed water must be
pre-filtered
from
fine
particles and chlorine
before
entering
the