Download Print this page

Brother HL-960 Series User Manual page 257

Brother hl-960: users manual

Advertisement

• When ISBN (EAN) is selected with the parameter "t130" or
"T130":
Same rules apply as for "t5" or "T5"
• When ISBN (UPC-E) is selected with the parameter "t131"
or "T131":
Same rules apply as for "t6" or "T6"
• When EAN 128 set A, set B or set C is selected with the
parameter "t132" or "T132", "t133" or "T133" or "t134" or
"T134" respectively:
Same rules apply as for "t12" or "T12", "t13" or "T13", or
"t14" or "T14".
Box Drawing
ESC i ... E (or e)
"E" or "e" is a terminator.
Line Block Drawing
ESC i ... V (or v)
"V" or "v" is a terminator.
Expanded Character Data Start
n = "l" or "L"
Data that follows "l" or "L" is read in as expanded character
data (or labeling data). Expanded character data must end
with the " \ " code (5CH), which also terminates this
command.
[Example Program Listings]
WIDTH "LPT1:",255
'CODE 39
LPRINT CHR$(27);"it0r1s0o0x00y00bCODE39?\";
'Interleaved 2 of 5
LPRINT CHR$(27);"it1r1s0o0x00y20b123456?\";
'FIM
APPENDICES
Appendix–65

Advertisement

loading