Cornelius IDC 2 Series Service Manual page 28

With cold carbonation
Hide thumbs Also See for IDC 2 Series:
Table of Contents

Advertisement

IDC 2XX Service Manual
No Carbonated Water
NO CARBONATED WATER
Does the
carbonator pump start
when the unit is
turned on?
No
Check the carbonator pump
connection to the E-Board in the E-
Box.
Publication Number: 621057403SER
Is the
Yes
incoming water
restricted?
No
Is there
power connection to
the carbonator
pump?
No
1. Check whether or not there is
power across the carbonator power
cord on the E-Board in the E-Box..
2. Change carbonator power cord on
the E-Board in the E-Box.
- 26 -
Restore the
Yes
recommended water flow.
Is the
Yes
pump motor
Yes
running?
No
Replace carbonator
pump.
1. Replace Carbonator
pump.
2. Check Y fitting on the
total flex manifold.
© 2007-2019, Cornelius Inc.