Flat Drinks
FLAT DRINK(S)
Is the
drink temperature
above 40 degrees
Fahrenheit?
No
Is CO2
being supplied to
the carbonator
tank?
No
1. Check CO2 supply tank.
2. Check CO2 supply lines.
3. Change CO2 tank.
© 2007-2019, Cornelius Inc.
Is there
Yes
ice on the cold
plate?
No
1. Fill the hopper with ice.
2. Dispense some ice to
ensure that the agitator
spreads ice on the cold
plate.
Is the
CO2 pressure in
Yes
the system
correct?
No
Adjust CO2 pressure
accordingly.
- 25 -
Check ice coverage on
Yes
the cold plate.
Does
the carbonator
Yes
cycle when a 20oz
drink is
dispensed?
No
Refer to carbonator
flow chart.
IDC 2XX Service Manual
Replace
Yes
carbonator pump.
Publication Number: 621057403SER